User's Manual
26
5.OO setup (continued)
Probe Mode on a Door Machine
5.O2 GUIDED SETUP (continued)
From the first screen, the user can change the Name of
the dispenser and the Short Name which is broadcast via
Bluetooth from the HOME screen.
To ensure that the right settings are configured, the user must
then indicate whether a probe is being used or not and then
select the Machine Type.
NOTE: Once Probe mode is selected, the DMx will
automatically determine the type of probe in use.
The options are:
• Basic Conductivity: “PROBE-C”
• Conductivity/Temp Compensated: “PROBE-CT”
• Inductive Probe: “PROBE-I”
Probe Mode on a Door Machine
To configure a DMx unit that utilizes a conductivity probe on a
Door Machine, start with the detergent pump first.
Detergent
Since the detergent is controlled by the reading of the probe,
there are several settings that must be configured to help the
dispenser operate accurately.
NOTE: The pump style (Motor or Solenoid) will automatically
be determined by the DMx controller.
Probeless Autoswitch (Door)
Probeless Autoswitch is a feature that, when enabled,
automatically switches the unit into Probeless mode if
problems are detected with the probe readings. More
specifically, if the probe reading is zero (0) or greater than
ninety (90) for a configured number of racks; it will trigger
the unit to switch to Probeless mode without interrupting the
operation. (When this occurs the Power and Detergent LEDs
will flash Yellow indicating the probe requires maintenance.)
If enabled in the Guided Setup, the user will be prompted to
establish the Probeless Dosing parameters for detergent, in
case a switch takes place.
For a door machine, this includes the initial charge time (0-200
sec) and the incremental dose time (1-20 sec).
Pulse Feeding
Pulse feeding is a feature for dosing in Probe Mode whereby
the detergent motor stops running continuously and begins
pulsing at a configured % of the setpoint. This allows the
dosing to be more precise and avoid overshooting the setpoint
if there is a time delay in between the detergent entering the
tank and its detection via the probe.
If enabled, there are multiple ways to configure when pulse
feeding will begin and the frequency of the pulses, as shown
on the next page.
Name
Settings
Pump
Selection