User's Manual

28
5.OO setup (continued)
5.O2 GUIDED SETUP (continued)
Liquid Pump Calibration (continued)
Liquid pumps can be calibrated using a fixed Time or fixed
Volume. Regardless of the method chosen, before beginning,
ensure that the pump is completely primed with the inlet and
outlet tubing filled with product.
NOTE: Liquid pumps are always calibrated at full speed. If the
speed for the rinse pump is then adjusted below the
maximum speed, the usage information will be scaled
proportionally.
Calibration by Time
When calibrating by time, the pump will run for a fixed time of
20 seconds. To begin the process:
1) With your container in position, press Start. The pump will
begin running and a countdown from 20 will begin. You can
cancel the process at any time by pressing Cancel.
2) Once the pump stops, enter the volume that was dispensed
in 20 seconds.
3) Check that the values are correct, and press Apply.
Calibration by Volume
Alternatively, users may opt to perform a calibration by volume.
Using this method, the pump must be started/stopped by the
user when it has dosed a set volume of product. To begin the
process:
1) The user must enter the volume they wish to dispense.
Hydro recommends that at least 4 oz (120 ml) be used for
volumetric calibrations.
2) With your container in position, press Start to begin the
process. The pump will begin running and counting from
zero. When the desired volume is dispensed press Stop.
3) Check that the values are correct, and press Apply.
Solenoid (Solids) Calibration
Calibrating a solenoid for solid chemical dispensing can only be done using a fixed Time and measuring the grams of product
dispensed.
It is important to measure the mass (always in grams) of the solid chemical container using a scale prior to beginning the
calibration process.
Probe Mode on a Door Machine