5.OO setup (continued)
5.O2 GUIDED SETUP (continued)
Solenoid (Solids) Calibration (continued)
Calibration by Time
When calibrating by time, the solenoid will open for a fixed
time of 20 seconds, allowing water to spray and dissolve the
solid product. To begin the process:
1) With outlet of the dissolver bowl routed to a drain or the
dish machine, press Start. The solenoid will open and a
countdown from 20 will begin. You can cancel the process
at any time by pressing Cancel.
2) Once the solenoid stops, weigh the solid chemical container
a second time and enter the mass (grams) dispensed over
the 20 seconds by taking the difference between the two
mass measurements.
3) Check that the value for the weight of solid product
consumed (in grams) is correct (see example at right),
and press Apply (not shown).
Rinse
1) To set up the rinse dispensing parameters for a unit
operating in Probe Mode on a Door Machine, scroll to the
top and select the Rinse Pump.
2) Next, enter the following:
• Rinse Aid Pump Speed (5-55 RPM): This is the speed
that the pump will run at whenever the rinse signal is active.
• Rinse Aid Time Delay (0-30s): This is the amount of time
that the rinse signal needs to be active before the rinse
pump will begin dispensing.
NOTE: Door machine setups utilize the Rinse Saver feature
that prevents the rinse pump from running more than
20 seconds per rack.
3) Set Rinse Aid Feed Option:
• Rinse on Rinse: The rinse pump will run whenever
the rinse signal is active as per the above configuration
parameters.
• Rinse on Detergent: The rinse pump will run whenever
the detergent signal is received active as per the above
configuration parameters for a set duration that is entered
by the user (seconds). This option is not commonly used
but may be appropriate on machines without a separate
rinse signal.
Rinse Time
Settings
Rinse Aid
Feed Option
Probe Mode on a Door Machine
Select
Rinse
Pump
Weigh
Solids
Container
Enter
Weight
Difference