User's Manual
30
5.OO setup (continued)
5.O2 GUIDED SETUP (continued)
Sanitizer (3-Product Models Only)
1) To set up the sanitizer dispensing parameters for a unit
operating in Probe Mode on a Door Machine, scroll to the
top and select the Sanitizer Pump.
2) Next, enter the following:
Sanitizer Pump Speed (5-55 RPM): This is the speed that
the pump will run at whenever the rinse signal is active.
Accepting the Guided Setup
To complete the Guided Setup or complete changes made to
a prior setup, scroll to the bottom and press Apply.
Probe Mode on a Conveyor Machine
To configure a DMx unit that utilizes a conductivity probe on a
Conveyor Machine, start on the Guided Setup Screen.
1) Confirm that the blue button is set to Probe and select
Conveyor as the Machine Type.
2) When this is done, the user will be prompted to enter the
Conveyor Rack Time (in seconds). This setting helps the
dispenser count racks in Conveyor Mode.
• The field can be set from 0-90 seconds.
• Whereas Door Mode counts a rack every time the
detergent and rinse signals are cycled, in Conveyor Mode,
a rack is counted when the rinse signal is on continuously
for the configured Conveyor Rack Time.
• If you are unsure about what to enter as the Conveyor
Rack Time, you can measure the amount of time it takes
for a rack of dishes to pass through the rinse portion of the
conveyor.
Detergent
Probeless Autoswitch (Conveyor)
Probeless Autoswitch is a feature that, when enabled, automatically switches the unit into Probeless mode if problems are
detected with the probe readings.
More specifically, if the probe reading is zero (0) or greater than ninety (90) for a configured number of racks (enter in the field
titled “Trigger After”) it will trigger the unit to switch to Probeless mode without interrupting the operation.
Probe Mode on a Conveyor Machine
Press
Apply
Sanitizer
Settings