5.OO setup (continued)
5.O2 GUIDED SETUP (continued)
Probeless Autoswitch (Conveyor) (continued)
When this occurs the Power and Detergent LEDs will flash
Yellow indicating the probe requires maintenance.
If enabled in the Guided Setup, the user will be prompted to
establish the Probeless Dosing parameters for detergent, in
case a switch to Probeless Mode does take place.
For a Conveyor machine, this includes:
• Initial charge time (0-200 sec)
• Incremental dose time (1-20 sec)
• Dose Interval (1-3 Racks).
These fields are described in greater detail on page 32 on
Probeless Mode.
NOTE: All other detergent settings for Probe Mode on a
Conveyor Machine are programmed identically to
those on a Door Machine (see page 28).
Rinse
1) To set up the rinse dispensing parameters for a unit
operating in Probe Mode on a Conveyor Machine, scroll
to the top and select the Rinse Pump.
2) Next, enter the following:
• Rinse Aid Pump Speed (5-55 RPM): This is the speed
that the pump will run at whenever the rinse signal is active.
• Rinse Aid Feed Option:
• Rinse on Rinse- The rinse pump will run whenever the
rinse signal is active as per the above configuration
parameters.
NOTE: There is no Rinse Pump Delay in Conveyor Mode.
NOTE: There is no Rinse on Detergent setting in Conveyor
Mode.
Sanitizer (3-Product Models Only)
1) To set up the sanitizer dispensing parameters for a unit
operating in Probe Mode on a Conveyor Machine, scroll
to the top and select the Sanitizer Pump.
2) Next, enter the following:
Sanitizer Pump Speed (5-55 RPM): This is the speed that
the pump will run at whenever the rinse signal is active.
Calibrate Pump / Solenoid
Pump or solenoid calibration for Probe, Conveyor Mode is
done identically to the process described starting on page 27.
When all settings for Detergent and Rinse have been set, press
Apply to complete the Guided Setup.
Press
Apply
Probe Mode on a Conveyor Machine
Select
Rinse
Pump
Rinse Pump
Speed
Rinse Feed
Option
Sanitizer
Settings