User's Manual

32
5.OO setup (continued)
5.O3 GUIDED SETUP - Probeless Mode
From the first Guided Setup screen, the user can change the dispenser into Probeless Mode by pressing the gray button
labeled “Change Probe Configuration” and selecting “No”. The user can also select whether a temperature sensor is being
used in the wash tank and the machine type at this time.
If a user is operating in Probeless or Time Mode to dispense detergent, there are three possibilities for machine type that will
be explained in greater detail:
Probeless Mode, Door Machine
Probeless Mode, Conveyor Machine
Probeless Mode, Alternate (Alt) Door Machine
Probeless Mode on a Door Machine
Probeless Mode on a Door Machine
Detergent
In Probeless mode for a door machine, the dispensing of
detergent is configured for set amounts of time depending on
whether an initial charge or incremental dose is triggered.
Initial Charge (0-200s): An initial charge is meant to be
dispensed every time the tank is drained and refilled with fresh
water. In Probeless, Door Mode, it is triggered when a Rinse
signal is received that is not preceded by a Detergent signal
within 90 seconds.
Incremental Dose (0-20s): An incremental dose in Probeless,
Door Mode is dispensed each rack when the detergent signal
is triggered on for the 3 second signal acceptance time. When
this occurs, the incremental dose will dispense and the pump
will stop. To trigger another incremental dose, the rinse signal
needs to cycle on/off to count the current rack and then a new
detergent signal would need to be received.
Detergent
Settings