User's Manual

33
5.OO setup (continued)
5.O3 GUIDED SETUP - Probeless Mode (continued)
Detergent (continued)
Calibrate Pump / Solenoid
Pump or solenoid calibration for Probeless, Door Mode is done
identically to the process described starting on page 27.
Rinse
1) To set up the rinse dispensing parameters for a unit
operating in Probeless Mode on a Door Machine, scroll
to the top and select the Rinse Pump.
2) Next, enter the following:
Rinse Aid Pump Speed (5-55 RPM): This is the speed
that the pump will run at whenever the rinse signal is active.
Rinse Aid Time Delay (0-30s): This is the amount of time
that the rinse signal needs to be active before the rinse
pump will begin dispensing.
NOTE: Door machine setups utilize the Rinse Saver feature
that prevents the rinse pump from running more than
20 seconds per rack.
3) Set Rinse Aid Feed Option:
Rinse on Rinse: The rinse pump will run whenever
the rinse signal is active as per the above configuration
parameters.
Rinse on Detergent: The rinse pump will run whenever
the detergent signal is active as per the above configuration
parameters for a set duration that is entered by the user
(seconds). This option is commonly used on the Door
machines seen in Europe.
Sanitizer (3-Product Models Only)
1) To set up the sanitizer dispensing parameters for a unit
operating in Probeless Mode on a Door Machine, scroll
to the top and select the Sanitizer Pump.
2) Next, enter the following:
Sanitizer Pump Speed (5-55 RPM): This is the speed that
the pump will run at whenever the rinse signal is active.
Calibrate Pump / Solenoid
Pump or solenoid calibration for Probeless, Door Mode is done
identically to the process described starting on page 27.
When all settings for Detergent and Rinse have been set, press
Apply to complete the Guided Setup.
Rinse Pump
Settings
Rinse Feed
Option
Press
Apply
Probeless Mode on a Door Machine
Select
Rinse
Pump
Sanitizer
Settings