User's Manual

36
5.OO setup (continued)
5.O3 GUIDED SETUP - Probeless Mode (continued)
Probeless Mode on an Alternate (Alt) Door Machine
An Alternate Door Machine is a Door Machine that has two
independent solenoids for the fill and for the rinse process.
This means that there is no rinse signal active when the
system is filling, therefore the logic for dosing detergent initial
charges is different for an Alternate Door.
To configure a DMx unit that utilizes Probeless/Time mode on
an Alternate (Alt) Door Machine, start on the Guided Setup
Screen.
Confirm that the gray button is set to Probeless and select Alt
Door as the Machine Type.
When complete, press Next to continue setting up the dosing
parameters for Detergent and Rinse.
Detergent
Detergent settings for Probeless Mode on an Alternate (Alt)
Door Machine require the following fields to be set:
Initial Charge (0-200s): An initial charge is meant to be
dispensed every time the tank is drained and refilled with fresh
water. In Probeless, Alternate (Alt) Door Mode, it is triggered
when the detergent signal is received and stays on for 10
seconds. The detergent signal in this case should be wired
to a signal that is on once per drain/fill cycle such as an “on
light,” the on/off switch on the dish machine, or if present, or
an electrical tank heat circuit between the tank heater switch
and the thermostat. If the dish machine does not have the
appropriate signals, please contact Hydro Technical Support.
Incremental Dose (0-20s): An incremental dose is dispensed
in Probeless, Alt Door Mode after racks complete and are
counted (per the Rinse signal cycling on/off). The incremental
dose will dispense for the time setting, and the pump will stop.
To trigger another incremental dose, the proper number of
racks must be completed.
Dose Interval (Every 1-3 Racks): In some cases on
Alternate Door machine, the user may not want to inject
detergent on every rack. If that is the case, the Dose Interval
can be increased to dispense every 2 or 3 racks instead.
Calibrate Pump / Solenoid
Pump or solenoid calibration for Probeless Alternate (Alt) Door
Mode is done identically to the process described starting on
page 27.
Press
Next
Probeless Mode on a Alt Door Machine
Detergent
Settings