User's Manual

37
5.OO setup (continued)
5.O3 GUIDED SETUP - Probeless Mode (continued)
Probeless Mode on an Alternate (Alt) Door Machine (continued)
Rinse
1) To set up the rinse dispensing parameters for a unit
operating in Probeless Mode on an Alternate (Alt) Door
Machine, scroll to the top and select the Rinse Pump.
2) Next, enter the following:
Rinse Aid Pump Speed (5-55 RPM): This is the speed
that the pump will run at whenever the rinse signal is active.
Rinse Aid Time Delay (0-30s): This is the amount of time
that the rinse signal needs to be active before the rinse
pump will begin dispensing.
Rinse Aid Feed Option:
Rinse on Rinse- The rinse pump will run whenever the
rinse signal is active as per the above configuration
parameters.
NOTE: Alternate Door machine setups utilize the Rinse Saver
feature that prevents the rinse pump from running
more than 20 seconds per rack.
Sanitizer (3-Product Models Only)
1) To set up the sanitizer dispensing parameters for a unit
operating in Probeless Mode on a Alternate Door
Machine, scroll to the top and select the Sanitizer Pump.
2) Next, enter the following:
Sanitizer Pump Speed (5-55 RPM): This is the speed that
the pump will run at whenever the rinse signal is active.
Calibrate Pump / Solenoid
Pump or solenoid calibration for Probeless, Door Mode is done
identically to the process described starting on page 27.
When all settings for Detergent and Rinse have been set, press
Apply to complete the Guided Setup.
Select
Rinse
Pump
Rinse Pump
Settings
Rinse Feed
Option
Probeless Mode on a Alt Door Machine
Press
Apply
Sanitizer
Settings