5.OO setup (continued)
5.O4 SETUP FROM FILE
Setup From File allows the user to quickly configure a DMx
dispenser without manually configuring using the Guided
Setup. This saves time and installation cost, taking the process
from minutes to seconds. Setup files can be written using the
Hydro Connect Mobile Application and saved in the Hydro
Connect Cloud to offer a standard library that also prevents
user errors related to setup.
To access this menu from the first SETUP DISPENSER screen,
press the Setup From File button.
Configuring the Dispenser Using an Existing Setup File
After clicking on the Setup From File button, a list of the
applicable setup files will be pulled from the Hydro Connect
Cloud using the user’s credentials and the dispenser
serial number (e.g. for a 2-product system, only 2-product
configurations will be returned).
If there are many files listed, clicking the Activate Filters will
allow filtering by Probe Type (Probe-I, Probe-C, or Probeless)
and/or Machine Type (Door, Conveyor, or Alternate Door)
so that the list can be shortened and the correct file can be
chosen.
Once the desired setup file is chosen, the file will highlight blue
and the user can advance by selecting the blue Next button.
Final Edits
Before applying the selected configuration file, the user
has the opportunity to make any final edits to the applied
configuration by selecting one or more of the boxes noted
below.
NOTE: Making a change at this step, will not overwrite the
saved configuration file stored in the cloud and will
apply only to the device being configured.
File System Settings: Allows the user to modify the system
settings, such as the initial charge time or rinse pump speed.
File Configure Alarms: Allows the user to modify which
alarms are enabled and the corresponding settings.
File Advanced Settings: Allows the user to modify the
Advanced Settings like Priming Permission, Cost Information,
or the 24VDC output.
When all settings have been confirmed, press Apply All to
apply the loaded Setup configuration to the DMx dispenser.
NOTE: Calibration values for each pump, App Settings, and the site assignment from Asset Management are not transferred
as part of the Setup From File process and must be configured separately.
Press
Setup
From File
Final Edit
options
for loaded
Setup File
Press Apply
All to load
configuration
into Controller
Click
Setup File
to Select
Then click
blue Next
button
List of
Setup
Files