5.OO setup (continued)
5.O5 CONFIGURE ALARMS
The Configure Alarms menu allows each alarm to be enabled
or disabled, and for key settings for each alarm to be
customized.
To access this menu from the first SETUP DISPENSER screen,
press the Configure Alarms button.
The various states of operation are described below,
along with images showing the corresponding settings in the
application for the alarms described.
Condition: Normal Operation
LED color: Green - Flashing: Product LED
Buzzer State: Off
Description:
This condition can be seen on any product LED that is
operating normally as part of a rack or while priming with
no maintenance or critical alarms.
Condition: Normal Operation
LED color: Green - Fixed: Product LED
Buzzer State: Off
Description:
There is a detergent or rinse signal present and the pump is
not dosing
Condition: Out of Product Alarm
LED color: Red - Fixed: Product LED
Red - Fixed: Power LED
Buzzer State: On: 3 Short Beeps
(Press any Product button to mute buzzer.)
Description:
This alarm is caused when a depletion wand is being used
on detergent, rinse, or sanitizer when the drum reads
empty.
When this critical alarm occurs, the system will enter
standby mode with the Power LED turning red and at least
one product LED also turning fixed red. This indicates that
there is an out of product condition that the local staff can
manage.
The alarm can be cleared by replacing the empty container
and changing the state of the depletion wand float switch.
If the power button is pressed to take the system out of
standby mode, the alarm state will be checked again and
will be retriggered if the container is still out.
Condition: Low Detergent Alarm (Probe Mode Only)
LED color: Red - Fixed: Detergent LED
Red - Fixed: Power LED
Buzzer State: On: 3 Short Beeps
(Press any Product button to mute buzzer.)
(continued)
Press
Configure
Alarms
Configuration:
Out of
Product Alarms
DETERGENT RINSE AID SANITIZER POWER
Normal Operation
DETERGENT RINSE AID SANITIZER POWER
Normal Operation
DETERGENT RINSE AID SANITIZER POWER
Out of Product Alarm
DETERGENT RINSE AID SANITIZER POWER
Low Detergent Alarm