5.OO setup (continued)
5.O5 CONFIGURE ALARMS (continued)
Condition: Low Detergent Alarm (Probe Mode Only)
Description:
• This alarm is caused if the conductivity probe reads below
the setpoint and has not increased by 10% for the number
of racks designated by the user.
• When this critical alarm occurs, the system will enter
standby mode with the Power LED turning red and the
Detergent LED also turning fixed red. This indicates that
there is an out of product condition that the local staff can
manage.
• The alarm can be cleared by pressing and holding the
Detergent button for at least 2 seconds. Alternatively, if the
power button is pressed to take the system out of standby
mode, the alarm state will be cleared.
Condition: Faulty Probe (Probe Mode Only)
LED color: Red - Flashing: Detergent LED (1 / second)
Red - Fixed: Power LED
Buzzer State: On: 3 Short Beeps
(Press any Product button to mute buzzer.)
Description:
• This alarm is automatically enabled when the dispenser is
in Probe Mode and cannot be disabled in the Configure
Alarms menu.
• It indicates that there is a critical alarm on the detergent
pump and that the conductivity probe has read abnormally
low or high for a fixed number of 3 racks.
• The alarm can be cleared by pressing and holding the
Detergent button for 2 seconds or by taking the system out
of standby mode by pressing the Power button.
• If Auto-Switch is enabled, the system will perform as noted
in the Configure Alarms section on Faulty Probe with Auto-
Switch Enabled, immediately below.
Condition: Faulty Probe with Auto-Switch Enabled
LED color: Orange - Flashing: Detergent LED (1 / second)
Orange - Flashing: Power LED (1 / second)
Buzzer State: Off
Description:
• This indicates that the conductivity probe controlling the
detergent pump has read abnormally low or high for a
number of racks that exceeds the value set for Probeless
Autoswitch menu (1-5 racks). This means the probe is likely
faulty, or damaged. With Autoswitch enabled in the Guided
Setup, the unit will automatically revert to Probeless mode.
• To clear the alarm, the user can press and hold the
Detergent button for 2 seconds.
• To return to Probe mode, the probe should be serviced,
and the dispenser reconfigured for Probe mode in the
Guided Setup section of the Hydro Connect Mobile
Application.
Configuration:
Low Detergent
Alarm
Faulty Probe Alarm
DETERGENT RINSE AID SANITIZER POWER
Configuration:
Autoswitch
Enabled
Faulty Probe with Autoswitch Alarm
DETERGENT RINSE AID SANITIZER POWER