User's Manual
43
5.OO setup (continued)
5.O5 CONFIGURE ALARMS (continued)
Condition: Pump Jam
LED color: Red - Flashing: Product LED (2x / second)
Red - Fixed: Power LED
Buzzer State: On: Continuously
(Press any Product button to mute buzzer.)
Description:
• This alarm is automatically enabled for any liquid/motor
pump and cannot be disabled in the Configure Alarms
menu.
• It indicates that there is a critical alarm on one of the
product pumps whereby the pump is jammed and drawing
too much current.
• The alarm can be cleared by pressing and holding the
affected product button for 2 seconds or by taking the
system out of standby mode by pressing the Power button.
Condition: Low Rinse Temperature
LED color: Red - Flashing: Rinse LED (1 / second)
Red - Fixed: Power LED
Buzzer State: On: 3 Short Beeps
(Press any Product button to mute buzzer.)
Description:
• This indicates that the optional rinse temperature sensor
has detected that the maximum temperature recorded
while the rinse pump is running (measured once per
second) is below the configured Minimum Temperature set
in degrees Fahrenheit (150-212°F) or Celsius (66-100°C)
• The alarm can be cleared by pressing and holding the
Rinse button for 2 seconds or by taking the system out of
standby mode by pressing the Power button.
Condition: Low Tank Temperature
LED color: Orange - Fixed: Product LED
Buzzer State: Off
Description:
• This indicates that the optional temperature compensated
probe is reading a temperature value in the tank that is
below the setpoint that is set in degrees Fahrenheit (120-
212°F) or Celsius (49-100°C) in the Configure Alarms
menu.
• The alarm does not require immediate intervention and will
be reset when the temperature reading rises above the
setpoint again.
Configuration:
Low Tank Temp
Alarm
Low Tank Temperature Alarm
DETERGENT RINSE AID SANITIZER POWER
Configuration:
Low Rinse Temp
Alarm
Low Rinse Temperature Alarm
DETERGENT RINSE AID SANITIZER POWER
Pump Jam Alarm
DETERGENT RINSE AID SANITIZER POWER