User's Manual

45
5.OO setup (continued)
5.O6 ADVANCED SETUP
The Advanced Setup menu allows the operator to set up
features that reside outside of the basic dispenser functions,
such as User Prime Limits, Costs, and Asset Management.
To access this menu from the first SETUP DISPENSER screen,
press the Advanced Setup button.
Permission to Prime
Some sites may opt to disable or restrict the kitchen staffs
ability to prime the pumps without intervention through the
Hydro Connect Mobile Application. In the Advanced Settings
Menu, Permission to Prime can be toggled from Enable to
Disable. When Enabled, it is possible to set limits that would
only allow the user to prime for a set number of seconds (30-
90 sec) over a configurable number of hours (1-24 hours).
NOTE: Setting both the Prime For and Every time settings =
0s will allow the user to prime indefinitely. If the pump
is left running for 5 minutes, it will time out and stop
automatically.
For example, per the provided image, the user would only be
able to prime each pump for 30 seconds in any 8-hour period
before the prime buttons would lock out.
After the limit is reached, further attempts to prime will result in
the product LED flashing orange once, indicating that the user
must wait until the configurable lock-out period of 8-hours has
elapsed.
Cost Summary
This feature allows the chemical company to track the cost of
the chemical being consumed in the Hydro Connect Cloud.
The Cost Summary settings allow the chemical company to
enter the cost (USD, Euro, GBP, JPY, CAD, AUD, COP, MXN)
of their chemicals per Gallon, Ounce, or Liter (or Kg if using
Solid chemical formulations).
If the user wants to change the currency or volume units,
pressing the Change Units button will allow any of the above
options to be selected.
24V Output Control
There is a 24V DC output available on the DMx control
board that can be used to power an external alarm or other
accessory. This output is normally Disabled but can be
Enabled in the Advanced Settings Menu.
24V DC
Output Control
Change Units
Settings
Cost Summary
Settings
Permission to
Prime Settings
Press
Advanced
Setup