User's Manual
8
1.OO overview (continued)
1.O6 General Specifications
Category Specification
Electrical
Input Voltage 100-230 VAC at 50/60 Hz up to 1.0 Amps maximum (Class I)
Power Usage 24W maximum
Detergent Signal Input 24-250VAC at 50/60Hz up to 20mA or 24VDC up to 20mA
Rinse Signal Input 24-250VAC at 50/60Hz up to 20mA or 24VDC up to 20mA
Weights and Dimensions 2-Product Models 3-Product Models
Weight: Unboxed Nominal: 1.8 Kg (4.0 lbs) Nominal: 2.5 Kg (5.5 lbs)
Boxed Nominal: 5 Kg (11 lbs) Nominal: 5.9 Kg (13 lbs)
Dimensions: Unboxed
247 mm Wide x 185 mm High x 134 mm Deep
9.7 in Wide x 7.3 in High x 5.3 in Deep
361 mm Wide x 201 mm High x 134 mm Deep
14.2 in Wide x 7.9 in High x 5.3 in Deep
Boxed
558.8 mm Wide x 279.4 mm High x 279.4 mm Deep
22 in Wide x 11 in High x 11 in Deep
558.8 mm Wide x 279.4 mm High x 279.4 mm Deep
22 in Wide x 11 in High x 11 in Deep
Operating Environment
Ambient Temperature 10°C minimum to 50°C maximum (50°F minimum to 120°F maximum)
Humidity 95% relative humidity maximum
Indoor Installation Indoor Use Only. Must not be installed outdoors.
Pump Performance *
Peristaltic Pumps (Flow rates indicated below are nominal.)
* Always test with actual chemical, at
installation, for accurate flow rate.
Detergent Pump: 355 ml/min (12 oz/min)
Rinse/Sanitizer Pump:
15 ml/min (0.5 oz/min) Maximum (Adjustable)
Inlet Water *
Water Temperature Water Pressure
* For Solenoid equipped models only.
5°C minimum to 60°C maximum
(40°F minimum to 140°F maximum)
Min: 2 Bar / 0.2 MPa / 30 PSI
Max: 6 Bar / 0.6 MPa / 90 PSI
Regulatory Approvals
UL 60730-1:2016Ed.5,CSA E60730-1:2015 Ed.5, IEC 60730-1:2013Ed.5+C1 Automatic Electrical Controls -
Part 1: General Requirements
CENELEC EN 61326-1*CEI 2013/01/01 Electrical Equipment for Measurement, Control and Laboratory Use –
EMC Requirements - Part 1: General Requirements
IEC61000-4-3 Radiated RF Susceptibility
IEC61000-4-6 Conducted RF Susceptibility
Part 15 - Class B digital device or
peripheral
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
1.O7 Intended Use
• The DMx Warewash Dispenser is intended for use in industrial applications and is not suitable for household use.
• The product must only be used for dispensing warewash detergents, rinse aids, and sanitizers.
• The dispenser has been tested using these typical chemicals, but to ensure compatibility with your formula contact us.
• The manufacturer waives any responsibility arising from incorrect usage or transportation.