User's Manual

9
2.OO installation
2.O1 Site Survey and Installation Requirements
Unit is to be installed by a trained technician; all local and national water regulations are to be observed.
Unit must be installed indoors, in an area that does not expose the unit to excessive temperature changes, direct sunlight,
frost or precipitation of any kind.
The area must be free of high levels of Electromagnetic Interference (EMI).
Ensure the unit will be mounted in an accessible location, above the height of the dishwasher’s detergent inlet.
The dispenser should be mounted close to the product containers--ideally, within 2 meters (6.6 feet).
The dispenser should be mounted close enough to the dish machine electrical control panel to allow dispenser wiring
without use of an external junction box (not provided) wherever possible. Wire harness is 3.5 meters (11.5 feet).
Installer must ensure the suitability of the wall or mounting substrate, which should be flat and perpendicular to the floor.
Unit location should be well lit for any maintenance, and should be free of high levels of dust particulates.
Scheduled maintenance should be carried out on the unit at least once per year.
It is a legal requirement that all water supply hose sets must be compliant with IEC 61770.
Ensure the chemicals being used are compatible with supplied tubing.
Safety Precautions
CAUTION: Before an installation takes place it is advisable to complete a site survey to ensure the DMx Warewash
Dispenser can be installed in a position that meets all the requirements below.
CAUTION: Do not install unit in potentially explosive environment where flammable gas, steam, fog or dust can form
an explosive combination with air.
WARNING: Electrical installation should be completed by a qualified electrician. All local and national electrical
regulations are to be observed.
2.1O Mechanical Installation
2.11 Mounting Bracket
1. Using the mounting bracket as a template, mark holes
to drill into mounting surface. For sheet metal mounting
with screws and nuts, drill 6 mm (1/4’’) holes. For wall
anchors, drill 8 mm (5/16 inch) holes.
2. Insert the two wall anchors into the drilled holes, pushing
them flush to the wall.
3. Secure the bracket to the wall with the two screws and
washers, using a #2 Phillips screwdriver or equivalent.
4. Hang unit on bracket.
NOTE: Ensure the wall
anchors are
suitable for the wall
being mounted to.