5600 Meter Initiated Valve Water Softener Operation Manual Read all instructions carefully before operation.
Performance and Specifications Item Number Model Number Capacity at regeneration salt levels (kilograins as CaCO3) Twin Tank Models 7600 5600MI-20 7601 5600MI-30 7602 5600MI-45 7603 5600MI-60 7604 5600MI-90 Cabinet Models 7378 WTC5620 7379 WTC5630 Service Flow Rate Maximum Flow To Drain Mineral Tank Size Brine Tank Size Resin Volume Salt Capacity Shipping Weight @15lb/cf @10lb/cf* @6lb/cf USGPM (LPM) USGPM (LPM) inches (mm) inches (mm) cu.ft. (litres) Lbs. (kg) Lbs.
Installation Instructions 1. Determine the best location for your water softener, bearing in mind the location of your water supply lines, drain line and 110 volt AC electrical outlet. Subjecting the softener to freezing or temperatures above 110°F (43°C) will void the warranty. 2. Water to supply outside faucets used to water lawns and gardens should not be softened. A new water line is often required to be connected to supply hard water to the inlet of the water softener and to the outside faucets.
7. Make sure the bypass valve is in the service position. 8. Set the time of day and the program wheel according to the instructions on page 4. 9. Remove back cover plate. Make sure that the salt dosage is set as recommended on page 5. NOTE: The various regeneration positions may be dialed manually by turning the large knob on the front of the control clockwise, until the indicator shows the desired position. 10. Turn the large knob to the backwash position.
Operating Instructions Setting the Time of Day (Figure 3) This is a 24-hour timer and must correspond with the correct time on your wrist watch to ensure proper cycling of your conditioner. Disengage the drive gear by pressing and holding in the RED BUTTON on the left side of the control. Now turn the large 24-hour gear until the actual time of day is at the time of day arrow at the bottom of the panel. Release the red button to re-engage the drive gear.
Salt Settings are factory set and should not need adjustment 5600MI-20 ................................8 lbs WTC5620 .................................7 lbs 5600MI-30 ..............................10 lbs WTC5630 ...............................10 lbs 5600MI-45 ..............................15 lbs 5600MI-60 ..............................10 lbs 5600MI-90 ..............................15 lbs Automatic Bypass The regeneration cycle lasts approximately 2-1/2 hours, after which soft water service will be restored.
Maintenance Checking the Salt Level Check the salt level monthly. Remove the lid from the cabinet or brine tank, make sure salt level is always above the brine level (you should not be able to see water). Adding Salt Use only clean salt labeled for water conditioner use, such as crystal, pellet, nugget, button or solar. The use of rock salt is discouraged because it contains insoluble silt and sand which build up in the brine tank and can cause problems with the system’s operation.
Trouble Shooting Guide Before calling for service, follow the steps below, then MANUALLY REGENERATE your softener. PROBLEM CAUSE 1. Softener delivers hard water A. B. CORRECTION Bypass valve is open No salt in brine tank A. B. F. Plugged injector assembly Close bypass valve. Add salt to brine tank and maintain salt level above water level. C. Check salt setting and clean brine line flow control if plugged. D. Break salt bridging – see page 6. E.
GUARANTEE HYDROTECH guarantees that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble-free service. FIVE YEAR COMPLETE PARTS GUARANTEE HYDROTECH will replace any part which fails within 60 months from date of manufacture, provided the failure is due to a defect in material or workmanship.