Owner's manual

4
Operating Instructions
The valve has been pre-programmed with factory settings as follows:
Regeneration Cycle Step Programming
1. Backwash ..................................10 minutes
2. Brine Rinse..................................60 minutes
3. Rapid Rinse ................................10 minutes
4. Brine Refill ..................................10 minutes - 5600SEM-20
13 minutes - 5600SEM-30
10 minutes - 5600SEM-45
13 minutes - 5600SEM-60
20 minutes - 5600SEM-90
Set Time of Day
Refer to Figure 4. Push either the UP or DOWN keys to adjust the time of day by one digit. Press and hold either UP or
DOWN key to adjust time of day by several digits.
Enter Control Programming Mode
1. Push and hold for 5 seconds both the UP and DOWN keys to enter Programming Mode.
2. The first option display to appear is the Treated Water Capacity. To calculate the Treated Water Capacity, use the
following formula:
Unit Capacity in Grains (see Specifications - Page 1)
÷ water hardness (gpg) = gallons
gallons - (75 gallons x no. people in the house) = Treated Water Capacity
Example: 27,000 grain capacity unit, 20 gpg water hardness, 4 people in household
27,000 grains ÷ 20 gpg = 1,350 gallons
1,350 gallons - (75 gallons x 4) = 1,050 gallons
Set Treated Water Capacity to 1,050 gallons
3. Push the Extra Cycle button to advance to the second option setting. The setting that appears is the Regeneration
Time. Use the UP or DOWN keys to set the desired time of day for regeneration. The default setting is 2:00 A.M.
4. Push the Extra Cycle button. The third option setting display that appears is Regeneration Day Override. Use the
UP or DOWN keys to set the maximum days before a regeneration cycle must occur. The default is
{A--Off). This is an option only, please do not adjust before consulting an authorized dealer.
5. The Control Programming is now complete. Push the Extra Cycle button. This will exit the control from the
Programming Mode and resume to normal operation.
Figure 4
Set Down Button
Set Up Button
P.M. Indicator
Flow Indicator:
Flashing Dot With Water Flow
Service Indicator:
Valve in Service - Dot On
Extra Cycle Tonight - Flashing Dot