Owner's manual

6
1. The first option setting display that appears in the Program Mode is Treated Water Capacity. Using the
Set Up or Down Buttons, set the amount of treated water that can flow through the unit before a
regeneration is required. For Example:
2. Push the Extra Cycle Button. The second option setting display that appears is Regeneration Time. Using
the Set Up or Down Buttons, set the desired time of day when a regeneration can occur, is required. For
Example:
3. Push the Extra Cycle Button. The third option setting display that appears is Regeneration Day Override.
Using the Set Up or Down Buttons, set the maximum number of days before a regeneration cycle must
occur. For Example:
650 Gallons Capacity
2:00 A.M. Regeneration Time
Regenerate Every
7 Days Minimum
Service
Program
Flow
P. M.
650
Service
Program
Flow
P. M.
2:00
Service
Program
Flow
P. M.
A--7
Program Mode Indicator:
Program Mode Entered - Dot On
Extra Cycle Button
Set Up
Button
Set Down
Button
This is an option only. Please do not adjust before consulting an authorized dealer.