Manual

Installing the Disinfection Unit
Attaching unit
to wall
Follow these steps to attach WEDECO UV disinfection chamber to the wall.
Step Action Diagram
1 Install the two wall mount brackets on the
wall using the proper screws for your wall
type (screws not included).
2 Place disinfection chamber in the brackets
and secure with the wall mount bracket
straps. Use the wall mount bracket strap
screws provided to tighten the wall mount
bracket straps to the wall mount brackets.
3 The disinfection chamber must be properly
grounded prior to powering up the system.
Attach the ground wire to the stud and nut
located on the lower area of the
disinfection chamber and connect it to the
earth strap that is located at the bottom left
of the electrical box. (Grounding wire
included.)
8