User's Manual

DS-6210 Base Station Owner's Manual Product Controls
11
Name Color Status Description
On
The active BSCU links with the standby BSCU
properly.
Flashing
Data is being transferred or received between the
standby BSCU and active BSCU.
BAK Green
Off
The link is abnormal or not connected between the
standby BSCU and active BSCU.
On The BSCU links with the MCB properly.
Flashing
Data is being transferred or received between BSCU
and MCB.
MCB Green
Off
The link is abnormal or not connected between
BSCU and MCB.
On The BSCU links with the LNA properly.
Flashing
Data is being transferred or received between BSCU
and LAN.
LAN1-2 Green
Off
The link is abnormal or not connected between
BSCU and LAN.
Table 2-4 Descriptions on BSCU Indicators
2.4.4 Power Support Unit (PSU)
The PSU consists of power monitoring board, power module and LED panel.
2.4.5 Function
All functions of PSU are described in Table 2-5.
No. Item Description
1 External power supply input 90~264V AC 47~63Hz
2
Voltage output (for main
device)
13.5V DC
3 Voltage output (for CHU PA) HVCC˄13.5V DC˅