Relative humidity 5 % to 85 % (non-con-
densing)
Degree of protection IP20
Altitude for operation max. 4000 m (13 123 ft)
Transport
(in original packaging)
Temperature range -40 °C to +70 °C (-40 °F to
+158 °F)
Storage
(in original packaging)
Temperature range -40 °C to +70 °C (-40 °F to
+158 °F)
4.2 Switching on the DIB-R5 advanced
The product is switched on via an on/off switch on the connection and control panel. After
switching on the DIB-R5 advanced, the integrated hardware components will automati-
cally start up. Connections will be enabled. All the components are started up after
approx. three to five minutes.
To switch on the product, the connections must have been made properly and the voltage
source at the installation site must have been switched on already. The procedure for
switching on the voltage source depends on the circumstances at the respective installa-
tion site.
Several on/off switches with redundant voltage supply feeds
With redundant voltage supply feeds (optional), the DIB-R5 advanced features two on/
off switches and two separate voltage sources, if necessary. Each of them has to be
switched on for commissioning the product.
Switching on the DIB-R5 advanced
Preparation:
n The DIB-R5 advanced must be connected with the earthing system of the voltage
source at the installation site.
n All required connecting cables as well as antennas must be connected.
n The alarm contacts must be wired.
1. Switch on the voltage source via the corresponding equipment at the installation
site.
2. Set the on/off switch to the switch position "ON", refer to Figure 8.
ð
The integrated hardware components start up.
You have successfully switched on the DIB-R5 advanced.
Operation
Switching on the DIB-R5 advanced
DIB-R5 advanced
66 Operation Manual 90DIBR5advancedOM02 - 1.0