4.3.3.1 Checking operating states (via LEDs)
The following table provides an overview of hardware components whose LEDs can be
checked.
Checking operating states (via LEDs)
Hardware component Described in
TETRA Channel Unit (CHU)
Ä
Table “Legend: Indicators (LEDs) of the
CHU” on page 44
Base Station Controller Unit (BSCU)
Ä
Table “Legend: Indicators (LEDs) of the
BSCU” on page 46
Fan unit
Ä
Table “Legend: Indicators (LEDs) of the
fan unit” on page 51
Power Supply Module (PSM) with V
AC
voltage supply
Ä
Table “Legend: PSM (front view)” on
page 35
4.3.3.2 Checking operating states (audible check)
Upon switching on the DIB-R5 advanced, the fans briefly rotate at high speed and are
then adjusted according to the room temperature. No grinding or rattling noise should be
present at this time.
Checking operating states (audible check)
Preparation:
n The DIB-R5 advanced must be switched on.
n The front equipment rack door must be open.
Check whether grinding or rattling noise can be heard.
ð
If the corresponding noises can be heard, you must perform a fault analysis.
The function test has been completed.