User's Manual

Table Of Contents
5. In the Equipment view, check whether all application connections are displayed in
green.
ð
If application connections are shown in red, you must perform a fault analysis,
refer to NMC-511 FaultManager user manual.
You have successfully checked the operating states.
4.3.4 Checking the availability
After network elements have been connected with an existing switch or router at the site,
it must be checked whether the respective network element can be reached via the IP
address of the BSCU. The NMC-511 FaultManager is used to check whether the IP
address can be reached. If this should not be possible, the ping command should be
used to check whether it can be reached.
IP addresses of installed components
The configured IP addresses can be displayed via the NMC-511 FaultManager in the
Properties view and are also documented in the project-specific documentation.
Checking the availability
Preparation:
n The NMC or service computer must have been connected with the transport network.
n The NMC-511 FaultManager must have been started.
1. Check the state of the connections in the Visualization view of the NMC-511 Fault-
Manager.
Optional work step
The work steps described below are required only if the NMC-511 FaultManager cannot
check whether the network element can be reached or if no connection exists.
2. Use the Equipment view of the NMC-511 FaultManager to navigate to the corre-
sponding network constituent (hardware or software component).
3. Change to the Properties view and record the required IP address.
4.
Click on “Windows Start menu è Programs è Accessories è Command prompt”.
ð
The command prompt is displayed.
Operation
Function tests and operational monitoring > Checking the availability
DIB-R5 flexibleTx
70 Operation Manual 90DIBR5flexibleTxOM02 - 1.2