ER-600 Wireless Router User Manual eTung Technology Co. Ltd 2nd Floor Building 3, Beike Industrial Park, No.7 Feng Xian Mid Road, Haidian Dist. Beijing TEL:4008-909-611 FAX:010-64857815 Website: www.etungtech.com.
ER-600 User Manual Table of Contents 1. Product Introduction ....................................................................................................... 4 Brief Introduction ......................................................................................................... 4 Product Outlook ............................................................................................................ 5 Standard Accessories ....................................................................
ER-600 User Manual 1. Product Introduction This chapter mainly introduces the outlook, accessories, specifications and mechanism of ER-600. 1. 2. 3. 4. 5. 6. 7. Brief Introduction Product Outlook Accessories Dimension Working Mechanism Specifications Typical Usecases 1.1 Brief Introduction ER-600 is an industrially designed product that embeds industrial 4G wireless communication module. It has capability of high-speed Internet access, high-speed video and data transmission.
ER-600 User Manual at the same time. ER-600 can use WAN or WIFI network: in case cable network is available, WAN (LAN1) port can be used to access cable network; and in case WIFI is available, ER-600 can be configured to access internet via WIFI. 4G, WAN and WIFI are all supported by ER-600, this greatly facilitates customer’s project deployment that customers do not have to choose different devices from different suppliers because of different network access at the spot.
ER-600 User Manual Figure 1-1: ER-600 side view 1 Figure 1-2: ER-600 side view 2 6
ER-600 User Manual 1.
ER-600 User Manual Figure 1-5: GPS antenna Figure 1-6: Cross cable NOTE: The accessories may be different because of different models and customer requirements, the figures above are just for reference.
ER-600 User Manual 1.
ER-600 User Manual 1.5 Working Mechanism Figure 1-9: ER-600 working mechanism ER-600 connects with PC via Ethernet cross cable, and set PC’s IP address as automatically obtained IP. After power on, it dials up into 4G network (or, via cable/WIFI network) and access Internet, then PC can access Internet via ER-600, and then access the application server.
ER-600 User Manual ER-600-N4: FDD-LTE WAN ER-600-W0:WIFI/WAN ER-600-W4: FDD-LTE WIFI/WAN ER-600-N4G: FDD-LTE WAN GPS Frequency: Band FDD-LTE B7 WIFI IEEE 802.11n/g/b: 2.4GHz GPS L1, 1575.
ER-600 User Manual Support flow control per month, and hours per month for internet access Support flow wakeup, phone wakeup and SMS wakeup 1.6.
ER-600 User Manual 1.6.3 Serial Port Definition Type RS-232 Pin 2 3 5 Definition RXD TXD GND Table 1-2: ER-600 RS232 serial port (Standard RS-232 DB9 male port) pin definition Type RS-485 Pin 485A 485B Definition A B Table 1-3: ER-600 RS485 serial port pin definition 1.6.
ER-600 User Manual 1.
ER-600 User Manual Figure 1-12: Implement virtual LAN via ER-600’s Virhub functionality Figure 1-13: Implement device remote control via ER-600 and Vircom functionality 15
ER-600 User Manual Figure 1-14: Use ER-600 to access LAN remotely via VPN 16
ER-600 User Manual 2. Device Configurations This chapter introduces how to use ER-600 and related parameters. 1. 2. 3. 4. 5. Configurations Parameters Restore to default Firmware Update Remote Configurations 2.1 Configurations 2.1.1 One cross Ethernet cable used to connect ER-600 with PC or customer device; One 4G all frequency sucking antenna; One power supply; One USIM card that can access internet. 2.1.
ER-600 User Manual 18
ER-600 User Manual Figure 2-1: Set IP address as "Automatically obtain IP address" Open IE browser, input address "http://192.168.1.1" and press Enter; Input "root" as username and "1234" as password, then press Enter to login web configuration interface and configure the device.
ER-600 User Manual It is clear to see each configuration item in the router configuration interface. To change some parameter, click it, modify and then save it, then reboot the router. Configure DTU functionality if serial port is used, with data center IP:Port as eyun.etungtech.
ER-600 User Manual Figure 2-4: Configure Virhub functionality 21
ER-600 User Manual 2.2 Configuration Parameters Each configuration menu has multiple parameters, and some of them have sub-menus. Details are described below. Configuration Menu Item Current status Network Select Wireless Basic Network Settings Description Show device information, connection and data transfer status. Configure to use wireless (4G), cable network (WAN) or WIFI, set ICMP host, and whether to allow external access.
ER-600 User Manual Advanced settings Link management Embedded center Proxy client data port parameters, choose serial port type. For ER-600-N4G that embeds GPS model, configure GPS report time interval here.
ER-600 User Manual Figure 2-5: Restore to default Or: press the RESET button continuously to reset it to default. 2.4 Firmware Update Ask eTung for firmware to update. The firmware (*.img) can be uploaded from local disk, or downloaded from a server from Internet. According to the description of "Configuring ER-600", connect ER with ER-600 via a cross Ethernet cable, open browser, inputhttp://192.168.1.
ER-600 User Manual Figure 2-6: Upload firmware If the firmware can be downloaded from a server, input download URL (please ask eTung technical support for the URL), and click “Upload/Download”: Figure 2-7: Download firmware from server Wait for a moment, until "Update" is shown, choose "Delete the Former File", then click “Update”. It will prompt the file system has been updated, the original settings is clear, and the system is rebooting.
ER-600 User Manual configuration page again. 2.5 Remote Configurations SMS commands and remote AT commands can be used on ER-600 to modify configuration parameters remotely. Details are described below: 1. Modify configuration parameters remotely via SMS The SMS to configure ER-600 parameters should follow the format below: SMS password;AT commands 1) SMS password is the "SMS wakeup password" as shown in wireless network settings of the web configuration interface, with "1234" by default.
ER-600 User Manual 2) AT+DC=addr,port,user,mode Configure data center parameters, with reply OK or ERROR. addr: data center address, either IP or domain port: data center port user: username mode: TCP or UDP 3) AT+PWD=passwd Set new SMS password, with at most 8 characters, exluding ",",":", "=", etc. It is adviced to use digits and English characters only. The reply is OK or ERROR. 4) AT+VIRHUB=0/1 Set whether to enabe Virhub or not, with reply OK or ERROR.
ER-600 User Manual 11) AT+INFO? Check device information. with reply below: OK:IMEI,version,IP address at Ethernet interface 12) AT+VIRHUB? Check status of Virhub, with reply below: OK:0/1 0: Virhub is disabled, 1: Virhub is enabled. 13) AT+UPDATE=url Update firmware, with reply OK or ERROR. The reply OK does not mean update is complete, but the command has been received and the update will start.
ER-600 User Manual Figure 2-8: Transfer Terminal remotely Remote AT commands are listed below: 1) AT 2) AT+MSERVER=addr, port Change data center address and port, with reply OK or ERROR. addr: data center address, either IP address or domain port: data center port 3) AT+USER=user Change DTU username, with reply OK or ERROR.
ER-600 User Manual 6) AT+UPDATE=url,md5 Update firmware, with reply OK or ERROR. The reply OK does not mean update is complete, but the command has been received and the update will start. To check whether update is successful, send AT+INFO? after 5 minutes and check whether the firmware version is changed. url: download URL of the new firmware, beginning with "http://". Make sure the device can access this url, for example it should not be a public URL if the device has a private net card.
ER-600 User Manual 15) AT+SER&PAR? Query user serial port parity, with the following reply: OK:par Par: N: no parity, O: odd parity, E: even parity 16) AT+VIRHUB&ENABLED? Query whether virhub function is enabled, with the following reply: OK:0/1 0: disable virhub function, 1: enable virhub function 17) AT+CM&TYPE=prot Set protocol type, with reply OK. prot:TCP、UDP、ETCP 18) AT+CM&HBI=interval Set heartbeat interval in seconds, with reply OK.
ER-600 User Manual forward the reply to 13801234567. 26) AT+VIRHUB&TAP_IP? Check the remote access IP address via Virhub, with reply: OK:x.x.x.x 27) AT+VIRHUB&TAP_MASK? Check the remote access netmask via Virhub, with reply: OK:x.x.x.x 28) AT+VIRHUB&TAP_IP=x.x.x.x Set the remote access IP address via Virhub, with reply OK. 29) AT+VIRHUB&TAP_MASK=x.x.x.x Set the remote access netmask via Virhub, with reply OK. 30) AT+GPS? Ask for GPS location data, the reply data format is shown below: $GPRMC,090758.
ER-600 User Manual Appendix 1: Configure ER-600 to Access Internet via 4G Network According to the description of Ch. 2.1 Configurations, login ER-600’s webpage, choose “Network Settings” -> “Network Select”, configure to use 4G to access Internet. For ER-600-N4, the default network settings are to use MOBILE (4G): Set Network to “MOBILE 4G”, press “Save” and then reboot ER-600. NOTE: Some ER-600 types does not have 4G module, and then cannot access Internet via 4G network.
ER-600 User Manual Appendix 2: Configure ER-600 to Access Internet via Cable/WIFI 1. Configure ER-600 to access Internet via cable network According to the description of Ch. 2.1 Configurations, login ER-600’s webpage, choose “Network Settings” -> “Network Select”, configure to use WAN to access Internet.
ER-600 User Manual Figure Appendix 2-2: Use 4G to access Internet by default Set “Network Select” as WAN, and then click “Save”; Choose “Network Settings” -> “WAN” to configure WAN parameters; There are three kinds of types: DHCP, PPPoE and STATIC. Choose PPPoE if cable MODEM is used to access internet, and choose DHCP or STATIC if a dedicated line or LAN is used to access internet. Use STATIC if the IP address is static or assigned manually, otherwise use DHCP.
ER-600 User Manual Figure Appendix 2-4: Configure PPPoE username and password When choosing STATIC, configure static IP, net mask, gateway and DNS accordingly: Figure Appendix 2-5: Configure static IP When choosing DHCP, no additional parameters need to configure: 36
ER-600 User Manual Figure Appendix 2-6: Configure DHCP Click "Save", and plug in Ethernet cable on LAN1 (WAN) of ER-600 and connect to the cable network, then reboot ER-600. After reboot, login ER-600's web configuration page, it can be seen that ER-600 has connected to the internet with WAN.
ER-600 User Manual Figure Appendix 2-7: ER-600 accesses Internet via WAN 2. Configure ER-600 to access Internet via WIFI ER-600-W0 and ER-600-W4 can access Internet via WIFI. According to the description of Ch. 2.1 Configurations, login ER-600’s webpage, choose “Network Settings” -> “Network Select”, set network as WIFI, then click “Save”.
ER-600 User Manual Figure Appendix 2-8: Set network as WIFI Choose “Network Settings” -> “WIFI Client”, to configure WIFI parameters.
ER-600 User Manual Figure Appendix 2-10: Search WIFI APs Choose WIFI AP in the list, select security type, and input pin, then click “Save”, and reboot ER-600.
ER-600 User Manual WAN will be disabled automatically once WIFI is enabled. After reboot, login ER-600's web configuration page, it can be seen that ER-600 has connected to the internet with WIFI. Figure Appendix 2-12: ER-600 accesses Internet via WIFI NOTE: Some ER-600 types do not have WIFI module, and then cannot access Internet via WIFI.
ER-600 User Manual Appendix 3: eYun Virhub Testing Case 1. Apply eYun account Access website http://3g.etungtech.com, press “Register”, and input registration information. Pay attention that the password should not be too simple. Input a correct email address, then after submit the system will automatically send a web link to the mailbox, just click the link to enable the account.
ER-600 User Manual Figure Appendix 3-2: Input registration information 2. Configure ER-600 Connect ER-600 with PC via Ethernet cross cable, and the IP address in PC is set to obtain automatically; Open browser and input URL: 192.168.1.1; Input username: root, and password: 1234 to login; Choose Virhub in the menu list; Input account, and then press “Save”; Choose “Reboot System” in the menu list, and reboot ER-600.
ER-600 User Manual 3. Install Virhub software Ask Virhub v5.x installation package from eTung (either from CD or eTung’s website), install it on the host pc according to Virhub’s installation guide. 4. Login in Virhub and start data transfer Run Virhub and click "Settings", input the username and password applied before.
ER-600 User Manual Figure Appendix 3-5: Configure Loopback adapter’s IP address Press “OK” after configuration, the software will set the IP address to the Loopback adapter. 2) Add device: if account name is not input when configuring Virhub function in ER-600, then use “Add Device” in Virhub software to add ER-600 to the account: press “Add Device”, and input the IMEI number of ER-600.
ER-600 User Manual If add device fails, please first make sure if the SVR2 led light is on, that means ER-600 has connected to eYun platform. If ER-600 does not connect to eYun platform, add device will fail. 3) Then Virhub configuration is complete, check if the communication between host pc and PLC is OK. Open a cmd window, input command: ping 192.168.3.
ER-600 User Manual Appendix 4: eYun Vircom Testing Case ER-600 has two user serial ports, so it can be used as a DTU to connect with PLCs that have serial ports, and perform remote program download and transparent data transmission. eYun platform and Vircom functionality make it easier to implement remote access of PLCs that have serial port. Below we will illustrate the implementation in detail. 1. Apply eYun account Access website http://eyun.etungtech.
ER-600 User Manual Figure Appendix 4-2: Input registration information 2. Configure ER-600 Connect ER-600 with PC via Ethernet cross cable, the IP address in PC is set to obtain automatically; Open browser and input URL: 192.168.1.1; Input username: root, and password: 1234 to login; Choose DTU function in the menu list; Input main DC IP: eyun.etungtech.
ER-600 User Manual Figure Appendix 4-3: Configure DTU parameters 49
ER-600 User Manual Figure Appendix 4-4: DTU connected to DC 3. Login Vircom and test communication Find Vircom installation package from eTung website: www.etungtech.com, and Download Center->DTU related, then download and install Vircom.
ER-600 User Manual Figure Appendix 4-5: Configure Vircom and choose mServer Figure Appendix 4-6: Add device Figure Appendix 4-7: Succeed to add device 51
ER-600 User Manual Figure Appendix 4-8: Map a virtual COM Figure Appendix 4-9: Succeed to map virtual COM 52
ER-600 User Manual Appendix 5: Use ER-600 to Access LAN Remotely via VPN ER-600 can be used to extend and access the corporate virtual LAN remotely with VPN function, for example, the user can use ER-600 to dial into corporate LAN. But the router in user's corporate LAN should support VPN in this way. We will illustrate below how to implement this kind of network connection with VPN. 1. System Architecture 2.
ER-600 User Manual as shown in the figure below: Figure Appendix 5-2: Configure router's VPN function Actually different routers have different configuration interface and options, we can configure it accordingly.
ER-600 User Manual Figure Appendix 5-3: Configure account for VPN function Type -- PPTP or L2TP VPN server IP or domain -- the IP address on corporate LAN side, if the IP address is not static, we recommend to apply a domain free of charge from Oray or Gnway, then input the domain here, ER-600 supports domain resolving. Username -- the username configured in the router at corporate LAN side, i.e.
ER-600 User Manual Figure Appendix 5-4: ER-600 status of accessing LAN At this time, ER-600 is connected to the corporate LAN, and visiting http://192.168.0.207 inside the corporate LAN can see ER-600's web login interface, and at the same time ER-600 can access resources inside the corporate LAN. If we connect a video server to ER-600, and configure port forwarding or DMZ host on ER-600, we can then access http://192.168.0.207 inside the corporate LAN and then access the video monitoring interface.
ER-600 User Manual Appendix 6: Configure GPS Query Settings and GPS data format ER-600-N4G embeds GPS model and supports device location. GPS location information can be actively transferred by ER-600 to the host PC, or: the host PC sends AT+GPS? command to query GPS location information, or: the device connecting ER-600 sends AT+GPS? command via serial port to query GPS location information.
ER-600 User Manual Figure Appendix 6-2: GPS data ①$GPRMC,090756.173,V,0000.0000,N,00000.0000,E,,,120211,,,N*7F ②$GPRMC,090758.182,A,3958.2382,N,11621.4878,E,1.06,201.56,120211,,,A*6A The figure above is the GPS data transferred to mServer, the data format is described below, with ② as an example. Name Example Unit Description Message ID RMC protocol header $GPRMC UTC Time hhmmss.sss, in the example it is 090758.182 09:07 and 58.
ER-600 User Manual According to the description above, it can be seen that ① is invalid GPS location information, and ② is valid GPS location information.
ER-600 User Manual Appendix 7: Send/Receive SMS with ER-600’s Ethernet Interface and SMS Format ER-600 supports sending/receiving SMSs via Ethernet interface. The method is described below: First, establish a TCP connection with the ER-600’s Ethernet IP (192.168.1.1 by default) and port: 8888; then use command AT+SMS or AT+SMSA to send SMSs.
ER-600 User Manual 1) In the left part “Client”, input ER-600’s Ethernet IP address “192.168.1.1” in “IP Address/Name”, and ER-600’s listening port “8888” in “Port”, then click “Connect” to establish TCP connection with ER-600; if “Connected” is shown Connection Status, that means TCP Test Tool has connected to ER-600’s listening port.
ER-600 User Manual Examples: Send “1234” with ASCII encoding to 13812345678: AT+SMS=13812345678,1,4,31323334\r Below is the command shown in hexadecimal: 41 54 2B 53 4D 53 3D 31 33 38 31 32 33 34 35 36 37 38 2C 31 2C 34 2C 33 31 33 32 33 33 33 34 0D Use 8bit encoding to send “1234”to 13812345678: AT+SMS=13812345678,2,4,31323334\r Below is the command shown in hexadecimal: 41 54 2B 53 4D 53 3D 31 33 38 31 32 33 34 35 36 37 38 2C 32 2C 34 2C 33 31 33 32 33 33 33 34 0D Use Unicode encoding to send “你好” to 138
ER-600 User Manual “1234” received from 13812345678 in 8bit encoding: \r\n+SMS:13812345678,2,4,31323334\r\n “你好” received from 13812345678 in Unicode encoding: \r\n+SMS:13812345678,3,4,4F60597D\r\n If the received SMS has more than one message, the format is as below: \r\n+SMSL:,,,,,,\r\n The messages with the same identifier can be assembled into one long SMS.
ER-600 User Manual Appendix 8: Send/Receive SMS with ER-600’s Serial Port ER-600 supports sending/receiving SMSs via user serial port. The method is described below: 1) Connect PC (or user device) with ER-600’s RS232 serial port via female-female RS232 cross cable; (Use RS485-to-RS232 converter if RS485 serial port is used on ER-600) 2) Go to ER-600’s configuration web page, according to Ch. 2.
ER-600 User Manual Figure Appendix 8-1: Configure ER-600’s serial port 3) Use command AT+SMS or AT+SMSA on PC (or user device) to send SMSs. For example, use tool Serial Interface on PC to send SMS, choose COM1 and set baud rate to 9600, then click “Connect”, then input AT command in the serial input box at the bottom and click “Send”; “OK” appears in the output box means that the SMS has been sent successfully.
ER-600 User Manual 4) Meanwhile, ER-600 can receive and output SMSs from the user serial port, as shown below: Figure Appendix 8-3: Receive and output SMS via ER-600’s serial port NOTE: 1) ER-600’s RS232 serial port is standard RS232 DB9 male interface, and if the user device’s serial port is also DB9 female interface, use a standard RS232 female-male cable to connect ER-600 and user device, otherwise us female-to-female cross cable to connect user device and ER-600.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.