z Pause input disable selection (No. 15 FPIO)
Parameter No. 15 defines whether the pause input signal is disabled or enabled.
Setting
Enable (use) 0
Disable (do not use) 1
The factory setting is “0 [Enable].”
z Servo ON input disable selection (No. 21 FPIO)
Parameter No. 21 defines whether the servo ON input signal is disabled or enabled.
Setting
Enable (use) 0
Disable (do not use) 1
The factory setting is “0 [Enable].”
z Home-return input disable selection (No. 40 FPIO)
Parameter No. 40 defines whether the home-return input signal is disabled or enabled.
Setting
Enable (use) 0
Disable (do not use) 1
The factory setting is “0 [Enable].”
z Operating-mode input disable selection (No. 41 FPIO)
Parameter No. 41 defines whether the operating-mode input signal is disabled or enabled.
Setting
Enable (use) 0
Disable (do not use) 1
The factory setting is “0 [Enable].”