Manual

18
6SHFL¿FDWLRQV
2.2 Name and Function of Each Part of the Controller
Indication of PIO pattern number
If you have multiple systems and a different PIO pattern is used for each system, it is recommended
that you specify an applicable PIO pattern number on each controller to prevent confusion.
Explanation of input/output signal pattern
NPN --- Sink type
PNP --- Source type
Explanation of motor drive-power cutoff circuit
INT --- ACON-C [Internal drive-power cutoff relay type]
EXT --- ACON-CG [External drive-power cutoff relay type]
On notational convention of types of actuators to be connected
The supported actuator type is specified as in the example below. Check that the correct actuator is
used when connecting cables.
Example: RCA-RA3C-I-20-10-50-A1-S
(Note) Refer to the operation manual for each network (CC-Link, DeviceNet and ProfiBus) as well for the
detailed explanation of the network connection specifications.
Motor connector
Encoder connector
Brake release switch
PIO connector
Connects the PLC and PIOs.
Mode selector switch
SIO connector
Connects the teaching pendant/PC.
Connects the motor cable.
Power-supply
terminal block
Status indicator LEDs
SV (green) --- The servo is on
A blinking green light indicates
that the automatic servo-off
mode is active.
A
LM (red) --- An alarm is present.
The motor drive-power cutoff
circuit is indicated here.
The PIO pattern number is specified here.
The input/output signal pattern is indicated
here.
Connects the encoder cable.
Address switch
The model of the connected
actuator is indicated here.