Owner's manual

Chapter 3 Installation and Wiring
Part 1 Installation
22
Part 1 Installation
As for the use environment, this product can be used in an environment of pollution degree 2
*1
or
equivalent.
*1 Pollution degree 2: Normally only non-conductive pollutants exist, which are expected to be
temporarily conductive due to condensation. (EN60947-5-1)
2. Installation Environment
(1) When installing and wiring the controller, do not block the ventilation holes provided for cooling.
(Insufficient ventilation will not only prevent the product from functioning fully, but it may also result in
failure.)
(2) Prevent foreign matter from entering the controller through the ventilation holes. Since the controller is
not designed as dustproof or waterproof (oilproof), avoid using it in a dusty place or place subject to
oil mist or splashed cutting fluid.
(3) Do not expose the controller to direct sunlight or radiant heat from a high heat source such as a heat-
treating furnace.
(4) Use the controller in a non-condensing environment free from corrosive or inflammable gases.
(5) Use the controller in an environment where it will not receive external vibration or impact.
(6) Prevent electrical noise from entering the controller or its cables.
Environmental Condition of Controller
Item Specification and description
Operating temperature range
0 ~ 40qC
Operating humidity range 10% ~ 95% (Non-condensing; conforming to JIS C3502 RH-2)
Storage temperature range
-25qC ~ 70qC (Excluding the battery)
Maximum operating altitude 2000 m
Protection class IP20
Vibration
10 d f < 57: 0.035 mm (continuous), 0.075 mm (intermittent)
57 d f d 150: 4.9 m/s
2
(continuous), 9.8 m/s
2
(intermittent)
X, Y and Z directions
Impact
147 mm/s
2
, 11 ms, half-sine pulse, 3 times each in X, Y and Z
directions