Instruction Manual

7. Operation of MEC Related Controllers
190
7) Ecology --- When Ecology is enabled, you can have the motor power (servo) turned off
automatically upon elapse of a specified period to save power after completion of
positioning. Set the applicable period beforehand using a parameter.
Parameter No. Parameter name
Initial
value
Setting
range
10 Auto servo OFF delay time [sec] 1 0 to 9999
[Pushing toward the end point or intermediate point]
[pushing toward the start point or intermediate point = Pulling]
Approach
Push complete
(A position complete
signal is output)
Speed
Push band
Start point Start position
of push
Time
End point
(intermediate point)
Return
Push complete
(A position complete
signal is output)
Speed
Time
Push band
End point
Start position
of push
Start point