User Manual

Page 68
10. Explanation on Each Function Screen
10.3-2 System Parameters
Parm
Axis
Sys
Prog
Posi
Srvo
Etc
Sys
Prog
Pos
Srvo
Etc
F1 F2 F3 F4
Parm System
Prog Pos Srvo Etc
F1 F2 F3 F4
Parm System Prog
1. Auto Start PRG
Inc [ <=]
0
Inc Dec Clr Wrt
System Program Parameter Mode
Inc
Dec
Clr
Wrt
F1 Key: +1 to column.
Return Key: +1 to column.
F2 key: - 1 to column.
*Automatic Start
Set the program number you wish to auto start to the “Auto Start Program” column located on the controller parameter side.
Upon completion, reset, emergency stop ON and install the power. Then, the set program will automatically start. This setting is
possible either by the teaching pendant or a PC software.
Precautions when using an Auto Start Program:
The servo actuator will start automatically, immediately after the controller is reset which may startle the operator. To ensure
safety, always use an interlock at the start of a program, such as having the actuator operate after receiving a confirmation signal.
To start simultaneous multiple-programming, set all other programs into EXPG command, placing them ahead of the main auto
program. As always, please take safety precautions when using an auto start program.
Application Program Reference
*
*
*
(* Reference only. Modification is not possible)
*