Owner manual
61
5. Explanation of Operating Functions
52
(Controller o PLC)
Register
Bit
address
Bit
position
Signal
symbol
Signal name Description
15
to
9
- - -
0147H 8 PZONE
Position zone
output
If individual zone boundaries are set in the
position table, this bit will turn “1” when the
current position enters the range specified
by the boundaries.
7
to
2
- - -
014EH 1 ZONE2
Zone output 2 This bit will turn “1” when the current
position enters the range specified by the
zone boundary 2 parameters.
Zone status
register
ZONS
Address
9013H
[Common]
014FH 0 ZONE1
Zone output 1 This bit will turn “1” when the current
position enters the range specified by the
zone boundary 1 parameters.
15
to
6
- - -
013AH 5 PM32
013BH 4 PM16
013CH 3 PM8
013DH 2 PM4
013EH 1 PM2
Position
number
status
register
POSS
Address
9014H
[POS
specification]
013FH 0 PM1
A completed position number is output
using a 6-bit binary code.
(Controller o PLC)
Register Address Description
PNOW
Current
position
[Numerical
specification]
The current position is indicated by a signed 32-bit intege
r
(unit: 0.01 mm).
A
negative value is indicated by a 2’s complement. Accordingly, the most significant bit
becomes “1.”
Upper
Lower
Si
g
n