Owner's manual
Table Of Contents
- Cover
- Please Read Before Use
- CAUTION
- CE Marking
- Table of Contents
- Safety Guide
- Caution in Handling
- 1. Overview
- 2. Installation
- 3. Wiring
- 3.1 Basic Structure
- 3.2 Configuration Using a SIO Converter
- 3.3 Configuration Using an Isolated PIO Terminal Block
- 3.4 Configuration Using Both SIO Converter and Isolated PIO Terminal Block
- 3.5 Specifications of I/O Signals
- 3.6 I/O Signals for PIO Pattern 1 [3 Points] (Air Cylinder)
- 3.7 I/O Signals for PIO Pattern 0 [8 Points]
- 3.8 I/O Signals for PIO Pattern 2 [16 Points] (Setting by Zone BoundaryParameters)
- 3.9 I/O Signals for PIO Pattern 3 [16 Points] (Setting in Zone Fields in thePosition Table)
- 3.10 Emergency-Stop Circuit
- 3.11 Extension Cable
- 4. Electrical Specifications
- 5. Data Entry
- 6. Operation in the “3 Points (Air Cylinder)” Mode
- 7. Operation in the “8 Points” and “16 Points” Modes
- 7.1 How to Start
- 7.2 Position Table and Parameter Settings Required for Operation
- 7.3 How to Execute Home Return
- 7.4 Home Return and Movement after Start (16 Points)
- 7.5 Positioning Mode (Back and Forth Movement between Two Points)
- 7.6 Push & Hold Mode
- 7.7 Speed Change during Movement
- 7.8 Operation at Different Acceleration and Deceleration Settings
- 7.9 Pause
- 7.10 Zone Signal
- 7.11 Incremental Moves
- 7.12 Notes on Incremental Mode
- 8. Parameter Settings
- 9. Troubleshooting
- 10. Maintenance and Inspection
- 11. Appendix
- Change History

99
6. Operation in the “3 Points (Air Cylinder)” Mode <Practical Operation>
90
6.4 Moving Operation
First, make the controller ready to accept movement commands by referring to 6.2, “How to Start.”
Example of use in operation) Turn on the power, and then cause the actuator to move back and forth between
the rear end (5 mm) and front end (390 mm) via an intermediate point (200 mm).
ERC2 controller
P
L
C
[1] [3] [12]
[8] [11]
[4] [7]
[2] [5]
[10] [13]
[6] [9]
PIO
Signal name
Rear end move
Front end move
Intermediate point move
Alarm reset
*Pause
Rear end complete
Front end complete
Intermediate point complete
*Alarm
Category
Input
Output
Reference flow
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
The rear end move input turns ON
Home return starts
The actuator hits the mechanical
ends and turns back
The actuator arrives and stops at
the home temporarily
The actuator starts moving to the rear end
The actuator arrives at the rear
end, upon which the rear end
complete output turns ON
The rear end move input turns OFF
The intermediate point move input
turns ON
The actuator starts moving to the
intermediate point
The rear end complete output turns OFF
The actuator arrives at the intermediate
point, upon which the intermediate point
complete output turns ON
The intermediate point move input turns
OFF
The front end move input turns ON
The actuator starts moving to the front end
The intermediate point complete output
turns OFF
The actuator arrives at the front
end, upon which the front end
complete output turns ON
The front end move input turns
OFF
The rear end move input turns ON
The actuator starts moving to the rear end
The front end complete output turns OFF