Owner's manual
Table Of Contents
- Cover
- Please Read Before Use
- CAUTION
- CE Marking
- Table of Contents
- Safety Guide
- Caution in Handling
- 1. Overview
- 2. Installation
- 3. Wiring
- 3.1 Basic Structure
- 3.2 Configuration Using a SIO Converter
- 3.3 Configuration Using an Isolated PIO Terminal Block
- 3.4 Configuration Using Both SIO Converter and Isolated PIO Terminal Block
- 3.5 Specifications of I/O Signals
- 3.6 I/O Signals for PIO Pattern 1 [3 Points] (Air Cylinder)
- 3.7 I/O Signals for PIO Pattern 0 [8 Points]
- 3.8 I/O Signals for PIO Pattern 2 [16 Points] (Setting by Zone BoundaryParameters)
- 3.9 I/O Signals for PIO Pattern 3 [16 Points] (Setting in Zone Fields in thePosition Table)
- 3.10 Emergency-Stop Circuit
- 3.11 Extension Cable
- 4. Electrical Specifications
- 5. Data Entry
- 6. Operation in the “3 Points (Air Cylinder)” Mode
- 7. Operation in the “8 Points” and “16 Points” Modes
- 7.1 How to Start
- 7.2 Position Table and Parameter Settings Required for Operation
- 7.3 How to Execute Home Return
- 7.4 Home Return and Movement after Start (16 Points)
- 7.5 Positioning Mode (Back and Forth Movement between Two Points)
- 7.6 Push & Hold Mode
- 7.7 Speed Change during Movement
- 7.8 Operation at Different Acceleration and Deceleration Settings
- 7.9 Pause
- 7.10 Zone Signal
- 7.11 Incremental Moves
- 7.12 Notes on Incremental Mode
- 8. Parameter Settings
- 9. Troubleshooting
- 10. Maintenance and Inspection
- 11. Appendix
- Change History

164
11. Appendix
152
Appendix
* Appendix
Example of Basic ERC2 Positioning Sequence
Given below is an example of basic sequence for creating a positioning sequence using the ERC2.
indicates PIO signals of the ERC2 controller.
Home return signal
HOME
HOME PEND
HEND
HOME
HEND
A
A
B
A
B
C
D
H
I
J
K
L
A C
D
C
C
I
H K
H
I
J
J PEND L
K
J PEND
L
Home return
request
Home return request
Positioning
start request
to position 1
Positioning
start request
to position 1
The positioning start request signal is converted to pulse in such a
way that one start signal is issued for one positioning operation.
Auxiliary start signal
for next positioning
({)
Check if positioning to the specified position has completed.
Positioning start pulse
to position 1
A
uxiliary positioning start
pulse to position 1
A
uxiliary positioning
start for position 1
Start check for position 1
Completion of positioning to
position 1
B
11.1.4 ERC2-RA7C
C
9
21 40
49
4
51.5
20
118.5
B
L
61
8.52
A 118.5
20
Stroke
M10
s
1.5
(300)
SIO type
F
45h7
M.E.
PIO type
50 100 150 200 250 300
L
A
B
C
312.5
194
423.5
106
2.7
362.5
244
523.5
156
2.9
412.5
294
623.5
206
3.0
462.5
344
723.5
256
3.2
512.5
394
823.5
306
3.3
562.5
444
923.5
356
3.5
Stroke
Weight [kg]
Home
Secure
at least
100
Teaching Port
M.E. : Mechanical End
Brake unit
Cable joint
connector
M10
s
1.5 Nut 3 types
64
7
50
32
1
68
64
50
89.6
4-
F
6.6
17 (2 flat faces)
(note) The angle of the 2 faces
on the actual product would
not be as shown in the drawing.
Appearance Figure for Brake-equipped Type
*Brake-equipped type is longer in 43.5mm and
weight heavier in 0.5kg than the standard type.
*There is no Teaching
Port for SIO Type.
Rod Diameter
F
30