Owner's manual

24
5. Precautions for Use
5.4 User Wiring and Piping
The robot comes with standard cables and tubes that the user can use in a desired wiring/piping
configuration.
Panel Rear panel
User connector specifications
Rated voltage 30 V
Permissible current 1.1 A
Conductor size and number of wires AWG 26 (0.15 mm
2
), 15 wires
Other Twisted-pair cable (1 to 14), shielded
Piping specifications
Normal service pressure 0.8 MPa
Dimensions (outer diameter x inner
diameter) and number of tubes
I4 mm x I2.5 mm, 3 pieces
Working medium Air
ALM (indicator) specifications
Rated voltage 24 VDC
Rated current 12 mA
Illumination color Red LED
Shape of Y-terminal Spacer for user part installation
M4, depth 5
30 N or less
External force applied to the spacers must not
exceed 30 N in the axial direction or 2 Nm in
the rotating direction (for each spacer).
2 Nm or less
I 7
10
2.6 5.9
5.2
3.2
BK SW
Brake-release switch
Quick joint I4 (red)
Quick joint I4
(black)
Quick joint
I4 (white)
Spacer for user part installation
User connector
A
LM (indicator)
A
ir tubes (I4 x 3 pcs.)
U cable (outside robot)
PG cable (outside robot)
BK power cable (outside robot)
Suction pipe joint
(Applicable tube: Outer diameter I12)
M cable (outside robot)