8. External Dimensions
73
8.8 S10HS
8.8.1 Standard Type
S10HS Standard Type
No. st L A B C D E Weight (kg)
1 90 475 1 44 8 144 198 9.2
2 180 565 1 134 8 234 248 10.0
3 270 655 1 224 8 324 298 10.9
4 360 745 2 14 12 414 348 11.7
5 450 835 2 104 12 504 398 12.5
6 540 925 2 194 12 594 448 13.4
7 630 1015 2 284 12 684 473 14.2
8 720 1105 3 74 16 774 523 15.0
9 810 1195 3 164 16 864 573 15.9
10 900 1285 3 254 16 954 623 16.7
11 990 1375 4 44 20 1044 673 17.6
12 1080 1465 4 134 20 1134 698 18.4
13 1170 1555 4 224 20 1224 748 19.2
14 1260 1645 5 14 24 1314 798 20.1
15 1350 1735 5 104 24 1404 848 20.9
16 1440 1825 5 194 24 1494 898 21.7
17 1530 1915 5 284 24 1584 923 22.6
18 1620 2005 6 74 28 1674 973 23.4
19 1710 2095 6 164 28 1764 1023 24.2
20 1800 2185 6 254 28 1854 1073 25.1
21 1890 2275 7 44 32 1944 1123 25.9
22 1980 2365 7 134 32 2034 1148 26.7
23 2070 2455 7 224 32 2124 1198 27.6
5
0
+0.012
4
2.7 1.8
5.5
3.3
5.8
10060
160
1
120
119
185
85
100
19
14
15
24
49
40
14
19
70
100(D)100
42.5 (B) 42.5
ME
SE
ME
L(st+385)
(55)
112.5 st 160 112.5
(55)5 5
E
165216
75
25 2550
85
6 15 6
21
80
97
70
16.5
1010
44
111
106
93
120
117
35
32
100
Detail view of G
Detail view of F
Reference
surface
Cable track for user (S type) Cable track for user (M type)
M3 T-slot
(F)
A×150
P
A×150
P
2-
φ
4H7,
reamed depth 5
2-slot,
depth 5 (G)
C-M5,
depth 10
HOME
Cable
4-M3, depth 5
(Reamer pitch: ±0.02)
65±0.02
4-M6, depth 10
2-
φ
6H7, depth 10
*The slider goes up the ME
in the home-return operation.
Pay attention to interference
to peripherals.
ME : Mechanical end
SE : Stroke end
Cable Track for User Wiring
Section Dimensions (S type)
Cable Track for User Wiring
Section Dimensions (M type)