User guide

9
7.1.2 Affixing the Actuator on the Bottom Side of the Base
Tapped mounting holes are provided at the back of the actuator base. Use these tapped holes to install
the actuator.
Tap diameter Effective tap length
M8 20 mm
Caution: Tapped holes are not through, so pay attention to the bolt length when selecting
bolts. Use of bolts of inappropriate length may damage the tapped holes or
reduce the mounting strength of the actuator, consequently leading to lower
precision or unexpected accident.
Tapped hole
Tapped hole