12. Maintenance and Inspection
45
12. Maintenance and Inspection
12.1 Inspection Items and Timings
Perform maintenance and inspection at the intervals specified below.
This schedule assumes that the actuator is operated eight hours a day.
If the actuator is operated at a higher utilization, such as when the machine is used continuously day and
night, reduce the inspection intervals accordingly.
Visual inspection
of exterior
Inspection of
interior
Grease
(N10SS, N10SM, N15SS, N15SM, N15HS, N15HM)
Start-up inspection
{
After 1 month of operation
{
After 6 months of operation
{{
After 1 year of operation
{{ {
Every 6 months thereafter
{
Every 1 year
{{ {
12.2 Visually Inspecting the Exterior
Visually check the exterior of the following items.
Inspection location Check items Remarks
Actuator Loosening of actuator mounting bolts, etc.
Cables Scratches, connector engagement
Stainless sheet Scratches, loosening Refer to Chapter 12 in this manual.
Overall Noise, vibration
* As a guideline, the service life of the stainless sheet roughly corresponds to a traveled distance of
5,000 km.
However, the stainless sheet may have to be replaced earlier depending on the use condition.
12.3 Cleaning the Exterior
x Clean the exterior surface as necessary.
x Wipe dirty areas using a soft cloth, etc.
x Do not blow highly compressed air onto the actuator, as it may cause dust to enter the actuator through
gaps between parts.
x Do not use petroleum-based solvent as it damages resin and coated surfaces.
x To remove stubborn stains, take neutral detergent or alcohol into a soft cloth, etc., and wipe the area
gently.