Manual
Chapter 7 Parameter
248
7.1 Parameter List
Each axis number has the following parameter table. Have the setting and checking on each
axis number.
The categories in the table below indicate whether parameters should be set or not. There are
five categories as follows:
A : Check the settings before use.
B : Use parameters of this category depending on their uses.
C : Use parameters of this category with the settings at shipments leaving unchanged as a
rule. Normally they may not be set.
D : Parameters of the category are set at shipment in accordance with the specification of
the actuator. Normally they may not be set.
E : Parameters of the category are exclusively used by us for convenience of production.
Changing their settings may not only cause the actuator to operate improperly but also to
be damaged. So, never change the setting of the parameters.
Category do not appear on the teaching tool.
Also, the unused parameter numbers are not mentioned in the list.
No.
Category
Name Symbol
Unit
(Note 1)
Input Range
Default factory
setting
Relevant
sections
1 B Zone 1 Positive Side ZNM1
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
(Note 2)
7.2 [1]
2 B Zone 1 Negative Side ZNL1
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
(Note 2)
7.2 [1]
3 A Soft Limit Positive Side LIMM
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
(Note 2)
7.2 [2]
4 A Soft Limit Negative Side LIML
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
(Note 2)
7.2 [2]
5 D Home Return Direction ORG -
0: Reverse
1: Normal
In accordance
with actuator
(Note 2)
7.2 [3]
6 C
Push & Hold Stop Judgment
Period
PSWT msec 0 to 9999 255 7.2 [4]
7 C Servo Gain Number PLGO - 0 to 31
In accordance
with actuator
(Note 2)
7.2 [5]
7.3
8 B Default Velocity VCMD
mm/s
[deg/s]
1 to Actuator’s
max. speed
Rated actuator
speed
(Note 2)
7.2 [6]
9 B
Default
Acceleration/Deceleration
ACMD G
0.01 to actuator's
max. acceleration/
deceleration
Rated actuator's
acceleration/
Deceleration
(Note 2)
7.2 [7]
10 B Default Positioning Width INP
mm
[deg]
0.01 to 999.99 0.10 7.2 [8]
13 C
Current-Limiting Value During
Home Return
ODPW % 1 to 300
In accordance
with actuator
(Note 2)
7.2 [9]
14 E Dynamic Brake FSTP -
0: Disabled
1: Enabled
1 7.2 [10]
15 B
Pause Input Disable
Selection
FPIO -
0: Enabled
1: Disabled
0 7.2 [11]
18 E
Home Position Check Sensor
Input Polarity
AIOF - 0 to 2
In accordance
with actuator
(Note 2)
7.2 [12]
19 E Overrun Sensor Input Polarity AIOF - 0 to 2
In accordance
with actuator
(Note 2)
7.2 [13]
20 E Creep Sensor Input Polarity AIOF - 0 to 2
In accordance
with actuator
(Note 2)
7.2 [14]
21 B
Servo ON Input Disable
Selection
FPIO -
0: Enabled
1: Disabled
0 7.2 [15]
Note 1: The unit [deg] is for rotary actuator. It is displayed in mm in the teaching tools.
Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the
parameters are set in accordance with the specification.