3.4 Fieldbus Type Address Map
104
3.4.3 Gateway Control Signals (in common for all operation modes)
When operating the system with Fieldbus, the axes are controlled via Gateway of MSEP. The
top 2 words of input and output in each operation mode are the signals Gateway control and
status monitoring.
(n is the top word address for each PLC input and output between MSEP and PLC)
PLC ĺ MSEP (PLC Output) MSEP ĺ PLC (PLC Input)
Control Signal 0 n Status Signal 0 n
Control Signal 1 n+1 Status Signal 1 n+1
(1) PLC I/O Signal
PLC Output
䎃
Address n
b15
b14 b13 b12 b11 b10
b9
b8 b7 b6 b5 b4 b3 b2 b1 b0
Control signal 0
MON
–
RTE
–
–
–
–
–
–
–
–
–
–
–
–
–
䎃
䎃
䎃
䎃
Address n+1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Control signal 1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
䎃
PLC Input
䎃
Address n
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Control signal 0
RUN
LERC
ERRT
MOD
ALMH
ALML
–
SEMG
ALMC
128
ALMC64
ALMC32
ALMC16
ALMC8
ALMC4
ALMC2
ALMC1
䎃
䎃
䎃
Address n+1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Control signal 1
MNT7
MNT6
MNT5
MNT4
MNT3
MNT2
MNT1
MNT0
LNK7
LNK6
LNK5
LNK4
LNK3
LNK2
LNK1
LNK0
䎃
䎃
Signal to cancel the remained condition of communication error
(ERR-T/ERR-C) during an operation
Signal to activate operation control by communication
Each type of control status monitoring output signals
Output of communication available axis numberOutput of alarm-issued axis number
1 word = 16 bit
1 word = 16 bit