3.4 Fieldbus Type Address Map
141
15) Reading of Alarm Code
PLC Output (Address n is the input and output top address for MSEP.)
(Note) If this command is sent, the response command updates with the latest information
until the demand command clear is sent.
䎃
Bit
Address b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
n+2
Demand
Command
[4001h]
0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
n+3
Data 0
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
n+4
Data 1
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
n+5
Data 2
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Reading of Alarm Code
n+6
Data 3
[Axis No.]
–
–
–
–
–
–
–
–
–
–
–
–
–
4
2
1
PLC Input (Address n is the input and output top address for MSEP.)
䎃
Bit
Address b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
n+2
Response
Command
[4001h]
0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
n+3
Data 0
[0]
–
–
–
–
–
–
–
–
128
64
32
16
8
4
2
1
n+4
Data 1
[Alarm Code]
n+5
Data 2
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Reading of Alarm Code
n+6
Data 3
[Axis No.]
–
–
–
–
–
–
–
–
–
–
–
–
–
4
2
1
1 word = 16 bit
1 word = 16 bit