Pressing Force and Current Limit Value
The correlation of the pressing force and the current limit value is the rated pressing speed (in
the setting at the delivery) and is a reference value.
Use the actuator with the setting above the minimum pressing force value. The pressing force
will be unstable if it is below the minimum pressing force value.
If the positioning speed setting in the operation condition is made lower than the pressing
speed, the pressing speed will follow that speed, thus cannot perform the expected pressing
force.
RA3C/RGD3C
RA4C/RGS4C/RGD4C
RCP2 Series
Rod Type
RA2C Type
Push force (N)
Current-limiting value (ratio, %)
100
80
60
40
20
0
0 10 20 30 40 50
RA2C-1
200
180
160
140
120
100
80
60
40
20
0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
0 10 20 30 40 50 60 70
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
0 10 20 30 40 50 60 70
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
200
180
160
140
120
100
80
60
40
20
0
300
250
200
150
100
50
0
300
250
200
150
100
50
0
80
70
60
50
40
30
20
10
0
800
700
600
500
400
300
200
100
0
400
350
300
250
200
150
100
50
0
500
450
400
350
300
250
200
150
100
50
0
RA4C-10
RGS4C-10
RGD4C-10
RA6C-16
RGS6C-16
RGD6C-16
RA4C-5
RGS4C-5
RGD4C-5
RA4C-2.5
RGS4C-2.5
RGD4C-2.5
RA6C-8
RGS6C-8
RGD6C-8
RA6C-4
RGS6C-4
RGD6C-4
RA3C-5
RGD3C-5
RA3C-2.5
RGD3C-2.5
RA6C/RGS6C/RGD6C
High-speed typeMedium-speed typeLow-speed type
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)
Push force (N)
Current-limiting value (ratio, %)