User Manual

Chapter 2 Wiring
63
2.4.8 Connection of PIO (for PIO Type)
The connection of I/O to the controller is to be carried out using the dedicated I/O cable. The
cable length is shown in the model code of the controller. There are 2m for standard, 3m and
5m as an option. 10m is also applicable at maximum if purchased separately. [Refer to 1.1.5
How to read the model]
Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut
and no treatment is conducted so the wiring layout can be performed freely.
Model: CB-MSEP-PIOƑƑƑ (ƑƑƑ indicates the cable length L. Example. 020 = 2m)
Flat Cable (34-core)
×
2
YW-8 (34B)
BR-5 (1B)
YW-4 (34A)
BR-1 (1A)
34A 34B
1A 1B
Half Pitch MIL Socket
HIF6-68D-1.27R (Hirose Electric)
A
B
L
No treatment
conducted
No treatment
conducted
No. Cable Color Wiring No. Cable Color Wiring
1A BR-1 1B BR-5
2A RD-1 2B RD-5
3A OR-1 3B OR-5
4A YW-1 4B YW-5
5A GN-1 5B GN-5
6A BL-1 6B BL-5
7A PL-1 7B PL-5
8A GY-1 8B GY-5
9A WT-1 9B WT-5
10A BK-1 10B BK-5
11A BR-2 11B BR-6
12A RD-2 12B RD-6
13A OR-2 13B OR-6
14A YW-2 14B YW-6
15A GN-2 15B GN-6
16A BL-2 16B BL-6
17A PL-2 17B PL-6
18A GY-2 18B GY-6
19A WT-2 19B WT-6
20A BK-2 20B BK-6
21A BR-3 21B BR-7
22A RD-3 22B RD-7
23A OR-3 23B OR-7
24A YW-3 24B YW-7
25A GN-3 25B GN-7
26A BL-3 26B BL-7
27A PL-3 27B PL-7
28A GY-3 28B GY-7
29A WT-3 29B WT-7
30A BK-3 30B BK-7
31A BR-4 31B BR-8
32A RD-4 32B RD-8
33A OR-4 33B OR-8
34A YW-4
Flat Cable
ż
A
(Press Welding)
AWG28
34B YW-8
Flat Cable
ż
B
(Press Welding)
AWG28