Owner manual

36
6.3 Alarms, Causes and Actions
(1) Alarms relating to the simple absolute unit (ACON, PCON)
Code Error Cause/action Alarm reset
0B6 Phase-Z
detection
timeout
Cause:
Phase Z could not be detected within the phase-Z output period of
the simple absolute unit.
[1] When the detail code is “H’0001”
Pole sensing + magnetic pole check
[2] When the detail code is “H’0002”
Operation after reversing, following home return and
push-motion operation
Action:
Check the wiring condition of the motor relay cable.
Check the wiring condition of brake cable, and turn on/off the
brake reset switch to see if “click” sound is heard.
Check if the mechanical parts are properly assembled.
Move the actuator away from the mechanical end and reconnect
the power.
If the load is normal, turn off the power and try moving it manually
to check the slide resistance.
{
Operation-
cancellation
level
0E5 Encoder
receive error
Cause:
[1] The controller is powered up before the simple absolute unit
when the 24-V power supply is turned on.
[2] When the detail code is “H’0001”
The simple absolute unit cannot communicate properly due to
noise, etc.
[3] When the detail code is “H’0002”
The controller cannot communicate properly with the simple
absolute unit because the communication line in the encoder
cable is disconnected.
Action:
[1] Make sure the simple absolute unit is powered up before (or
simultaneously with) the controller.
[2] Change the installation location of the controller. Implement
noise measures such as installing a FG, noise filter, clamp filter,
etc.
[3] Check the connectors on the encoder relay cable between the
controller and simple absolute unit for looseness. Or, replace
the cable.
X
Cold-start
level
0E8 Phase A/B
open
detection
0E9 Phase A open
detection
0EA Phase B open
detection
Encoder signals cannot be detected properly.
Cause:
[1] The connectors on the encoder relay cable are loose or
disconnected.
[2] Piano switch 4 is set wrongly.
Action:
[1] Check the connectors for looseness and disconnection.
[2] Check the switch setting by referring to 5.1.1, “Piano Switch
Settings.”
X
Cold-start
level