Manual

Chapter 9 Appendix
POWER CON
PCON-CA/CFA
246
[14] Other Display Circuits (Zone 1, Position Zone, and Manual Mode)
172
RMDS
Operation Mode
OUT7IN 1 1
RMDL
Manual Mode Display
170
PZONE
Position Zone
OUT6IN10
PZONEL
Position Zone Display
168
ZONE1
OUT6IN9
ZONEL
Zone 1 Display
[Reference]
Programs and functions of PLC are expressed differently depending on manufacturers. However,
the contents of sequence designs do not vary fundamentally. Though arithmetic and data
processing commands seem differently, any manufacturer defines command words executing the
same functions as those of other manufacturers.