Manual
4. SCON-CA
182
(14) Jog speed/inching distance switching (JVEL) PLC output signal
This signal switches between the parameter that specifies the jog speed to be used when the jog mode is
selected, and one that specifies the inching distance to be used when the inching mode is selected.
The relationships of applicable parameters are shown below.
JVEL signal Jog operation: JISL = OFF Inching operation: JISL = ON
OFF Parameter No. 26, “Jog speed”
Parameter No. 26, “Jog speed”
Parameter No. 48, “Inching distance”
ON Parameter No. 47, “Jog speed2”
Parameter No. 47, “Jog speed2”
Parameter No. 49, “Inching distance2”
(15) Jog/inching switching (JISL) PLC output signal
This signal switches between jog operation and inching operation.
JISL = OFF: Jog operation
JISL = ON: Inching operation
If the JISL signal switches to ON (inching) while the actuator is jogging, the actuator will decelerate to a stop and
the inching function will become effective.
If the JISL signal switches to OFF (jog) while the actuator is inching, the jog function will become effective after
the actuator completes its movement.
The table below specifies the relationship of the ON/OFF statuses of JISL signal and jog speed/inching distance
switching (JVEL) signal.
Jog operation Inching operation
JISL OFF ON
Speed Parameter No. 26, “Jog speed” Parameter No. 26, “Jog speed”
Travel - Parameter No. 48, “Inching distance”
JVEL=OFF
Acceleration/
deceleration
Rated value (the specific value varies
depending on the actuator)
Rated value (the specific value varies
depending on the actuator)
Speed Parameter No. 47, “Jog speed2” Parameter No. 47, “Jog speed2”
Travel - Parameter No. 49, “Inching distance2”
JVEL=ON
Acceleration/
deceleration
Rated value (the specific value varies
depending on the actuator)
Rated value (the specific value varies
depending on the actuator)
Operation When JOG+/JOG- is ON
Upon detection of the leading (ON) edge
of JOG+/JOG-