Owner's manual
4. PCON-CA/CFA
CC-Link
107
(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)
Signal Type Bit Symbol Description Details
Current
Position
32bits
Data
32-bit Integer with a Symbol
The unit is 0.01mm.
(Example)
Read Value: 000003FF
H
= 1023 (decimal system) = 10.23mm
* When it is read in hexadecimal notation, input the negative
value using a compliment of 2.
4.9 (2)
Command
Current
32bits
Data
32-bit Integer
It shows the current value in the current command.
The unit is mA.
Read Value: 000003FF
H
= 1023 (decimal system) = 1023mA
4.9 (2)
Current
Speed
32bits
Data
32-bit Integer with a Symbol
It shows the current speed.
Positive Figure: Under movement in the opposite direction of home
Negative Figure: Under movement in the home direction
The unit is 0.01mm/sec.
(Example)
Read Value: 000003FF
H
= 1023 (decimal system)
= 10.23mm/sec
* When it is read in hexadecimal notation, input the negative
value using a compliment of 2.
4.9 (2)
Alarm
code
16bits
Data
16-bit Integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0
H
”.
Refer to the instruction manual for the controller main body for
the details of the alarms.
4.9 (2)
b15 EMGS
Emergency Stop: “ON” for Emergency Stop Status
4.7.7 (2)
b14 PWR
Controller Ready: “ON” for Ready
4.7.7 (1)
b13 ZONE2
Zone 2: “ON” for the current position within the zone set range
4.7.7 (12)
b12 ZONE1
Zone 1: “ON” for the current position within the zone set range
4.7.7 (12)
b11
b10
b9
Unavailable
b8 RMDS
Operation Mode Status:
“OFF” for currently “AUTO” mode, “ON” for currently “MANU”
mode
4.7.7 (19)
b7
ALML
Light error status:
Turns ON when light alarm (threshold exceeded for number of
movement, etc.) that the operation can be continued with is
issued.
Note: ALM LED would not turn ON with a light error.
4.7.7 (31)
b6
Unavailable
b5 PSEL
Pressing and a Miss: “ON” for pressing and a miss
4.7.7 (23)
b4 SV
Operation Ready: “ON” with Servo ON
4.7.7 (5)
b3 ALM
Alarm: “ON” with alarm issue
4.7.7 (3)
b2 MOVE
Movement Signal:
“ON” with Actuator Movement
4.7.7 (9)
b1 HEND
Homing Completion
“ON” with Homing Completion
4.7.7 (6)
PLC Input
Status
Signal
b0 PEND
Positioning Completion Signal:
“ON” with Positioning Completion
4.7.7 (10)