Owner's manual
4. PCON-CA/CFA
CC-Link
152
(Example iv): In the case of the Value set to “3”:
䃂 shows ON. 䂾 shows OFF.
PCON
Input
register
1E 1F 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 F E D C B A 9 8 7 6 5 4 3 2 1 0
ON/OFF 䃂 䃂 䂾 䂾 䃂 䃂 䂾 䃂 䃂 䂾 䃂 䂾 䃂 䂾 䃂 䃂 䂾 䂾 䃂 䃂 䂾 䃂 䂾 䂾 䂾 䂾 䂾 䃂 䂾 䂾 䃂 䂾
Data in
Hexadecimal
Notation
C D A B 3 4 1 2
PLC䋺
RWwnn
1E 1F 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 F E D C B A 9 8 7 6 5 4 3 2 1 0
ON/OFF 䂾 䂾 䂾 䃂 䂾 䂾 䃂 䂾 䂾 䂾 䃂 䃂 䂾 䃂 䂾 䂾 䃂 䂾 䃂 䂾 䃂 䂾 䃂 䃂 䃂 䃂 䂾 䂾 䃂 䃂 䂾 䃂
Data in
Hexadecimal
Notation
1 2 3 4 A B C D
PCON
Output
register
1E 1F 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 F E D C B A 9 8 7 6 5 4 3 2 1 0
ON/OFF 䃂 䃂 䂾 䂾 䃂 䃂 䂾 䃂 䃂 䂾 䃂 䂾 䃂 䂾 䃂 䃂 䂾 䂾 䃂 䃂 䂾 䃂 䂾 䂾 䂾 䂾 䂾 䃂 䂾 䂾 䃂 䂾
Data in
Hexadecimal
Notation
C D A B 3 4 1 2
PLC䋺
RWrnn
1E 1F 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 F E D C B A 9 8 7 6 5 4 3 2 1 0
ON/OFF 䂾 䂾 䂾 䃂 䂾 䂾 䃂 䂾 䂾 䂾 䃂 䃂 䂾 䃂 䂾 䂾 䃂 䂾 䃂 䂾 䃂 䂾 䃂 䃂 䃂 䃂 䂾 䂾 䃂 䃂 䂾 䃂
Data in
Hexadecimal
Notation
1 2 3 4 A B C D
z FB Half Direct Mode Speed Unit (No.159 FBVS)
Determines the unit of measure when operating the unit in Half Direct Mode.
Parameter No. 159 Setting Value Speed Setting Unit
0 (Set in delivery) 1mm/sec
1 0.1mm/sec