Manual

56
(22) Jog Speed Default Value
Name Symbol Unit Input range
Default value
(reference)
Jog speed default value VEL pulse/sec 1~1092266 [A]
Set the default speed value used when performing jog operation with the PC software.
An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.
Calculation formula of the setting value (pulse/sec) of speed (mm/sec)
The setting value of the speed is converted from mm/sec to pulse/sec using the following formulae:
In the case of linear axis:
(mm/rev) length leadscrew Ball
)(pulse/rev pulses encoder of Number x (mm/sec) Speed
)(pulse/sec value Setting =
In the case of rotational axis:
rate reduction gear axis Rotational x (deg/rev) 360
)(pulse/rev pulses encoder of Number x (deg/sec) Speed
)(pulse/sec value Setting =
z The setting value of this item indicates pulses of the encoder, and is independent of the electronic
gear setting. The number of pulses of the encoder varies depending on the type of actuator. See (8),
“Number of Encoder Pulses.”
Caution