User Manual

MDI No. 00 A. 00
S
p
eed 125 mm/s
The screen will turn into the Input Screen for Speed.
The default value will be utilized as is. Since other
data will use the default value, input for position
number 0 will end here.
Next, position number 1 input will be executed.
Input using position number 1
MDI No. 01 A. 00
Position A
*
Press the
Key to advance position number to 1.
Position number 1
MDI No. 01 A. 00
Position A 5
0
The screen will turn into the Input Screen for Position.
Use the Numeric Keys to input 50 and then, press the
Return Key.
MDI No. 01 A. 00
S
p
eed 100 mm/s
The screen will turn into the Input Screen for Speed.
Use the Numeric Keys to input 100 and then, press
the Return Key.
MDI No. 01 A. 00
A
CC•DEC 0.1 G
The screen will turn into the Input Screen for ACC •
DEC. Use the Numeric Keys to input 0.1 and then,
press the Return Key.
MDI No. 01 A. 00
Push %
0 %
The screen will turn into the Input Screen for Push %.
The default value will be utilized as is, so press the
Return Key.
MDI No. 01 A. 00
Ran
g
e 0.2mm
The screen will turn into the Input Screen for Range.
Use the Numeric Keys to input 0.2 and then, press
the Return Key.
MDI No. 01 A. 00
A
CC MAX 1
The screen will turn into the Input Screen for ACC
MAX. Use the Numeric Key to input 1 and then, press
the Return Key.
MDI No. 01 A. 00
A
BS Æ 0 INC Æ 1 0
The screen will turn into the Input Screen for
A
BS/INC. The default value will be utilized as is, so
press the Return key.
Input for position number 1 will end here.
Next, position number 2 input will be executed.
21