(3) Clear:
The Clear operation procedure is explained below. The data of any position number is cleared.
In this example, the data of position number 1 is cleared.
The position data table becomes as shown below.
No. Position Speed ACC • DEC Push % Range ACC MAX ABS/INC
0 0.00 125 mm/s 0.20 G 0% 0.10mm 0 0
1 50.00 100 mm/s 0.10 G 0% 0.20mm 1 0
2 80.00 100 mm/s 0.10 G 40% 5.00mm 0 0
3 10.00 20 mm/s 0.20 G 0% 0.10mm 0 1
No. Position Speed ACC • DEC Push % Range ACC MAX ABS/INC
0 0.00 125 mm/s 0.20 G 0% 0.10mm 0 0
1 * * mm/s * G * % * mm * 0
2 80.00 100 mm/s 0.10 G 40% 5.00mm 0 0
3 10.00 20 mm/s 0.20 G 0% 0.10mm 0 1
Mode Select A. 00
* Edit/Teach
In the Mode Select Screen, using the
Keys,
select Edit/Teach and then, press the Return Key.
Edit/Teach A. 00
* Clear
In the Edit/Teach screen, using the
Keys,
select Add and then, press the Return Key.
Using the
Keys, change the position number
to 2. Pressing 1 on the Numeric Key will clear
position number 1 and then, the screen will return to
the Edit/Teach Screen. To cancel, press 0.
in
Position number 1
Clear? No. 01 A. 00
50.00 Y Æ 1 N Æ 0
Position data for
position number 1
In either case, the screen will return to the previous
screen.
Edit/Teach A. 00
* Clear
Mode Select A. 00
* Edit/Teach
Press the ESC Key once to return the screen back to
Mode Select Screen.